TROUBLESHOOTING
A) Atomiser disc spins but does not spray or sprays irregularly. Check:
−
The feed nozzle. If the feed nozzle is blocked remove and soak in soapy water.
Never blow through the nozzle with your mouth. Check that the feed nozzle
gives a flow rate within the operating range.
−
The atomiser is clean and undamaged. Clean or replace.
−
The flow valve for blockage. Rinse through with soapy water.
B) Atomiser disc fails to spin or spins unevenly. Check:
−
That the batteries are fitted correctly.
−
The condition of the batteries. Replace if necessary.
−
That electrical terminals and contact points are clean and that electrical wires are
not broken or corroded.
−
If the atomiser disc is rubbing on the motor base plate or the motor shaft is bent.
Replace the disc or motor if necessary.
−
The motor for corrosion or obvious signs of wear. Replace if necessary.
N.B. Battery condition can be checked with a torch (or a torch light bulb and electri-
cal wire).
-
+