Troubleshooting - Micron Herbidome 350 Instruction Manual

Table of Contents

Advertisement

A)
Atomiser disc spins but does not spray or sprays irregularly. Check:
− the metering/ calibration nozzle. If the metering/calibration nozzle is blocked
remove and soak in soapy water. NB. Never blow through the nozzle with
your mouth.
− the yellow feed nozzle. If the yellow feed nozzle is blocked remove and soak
in soapy water. NB. Never blow through the nozzle with your mouth.
− the atomiser disc is clean and undamaged. Clean or replace if necessary.
− the liquid ON/OFF valve for blockage. Clean if necessary.
B)
Atomiser disc fails to spin or spins unevenly. Check
− that the batteries and balance weight are fitted correctly.
− the condition of the batteries. Replace if necessary.
− that electrical terminals and contact points are clean and that electrical wires
are not broken or corroded.
− the motor for corrosion or obvious signs of wear. Replace if necessary.
− the atomiser disc is fitted correctly.

TROUBLESHOOTING

13