2.1.10 OUTPUT DC OFFSET

The DC offset present on the output is: < 20 mVDC.

2.1.11 OUTPUT PROTECTION

The output of the ACX Power Source is protected through the use of electronic current limiting.
The output will automatically recover when the output fault is removed. Thermal overload
protection is also provided. Refer to paragraph 2.3.5 for details.
The universal AC output socket that is located on the front of the ACX is limited to 10 A(RMS)
operation. It is protected by a 10A circuit breaker located at the rear of the power source. If the
current draw at the socket exceeds the 10A rating, the circuit breaker will disconnect power to
the socket. Reduce the load at the socket and press the circuit breaker button to reset.
NOTE:
The digital controller also provides programmable current limit.
Refer to the UPC Series Operation Manual for details.

2.1.12 OUTPUT CONTROL CHARACTERISTICS

Output control characteristics, sync I/O signals, and metering capabilities are determined by the
controller which is installed. Refer to the UPC Series Operation Manual for details.

2.1.13 OUTPUT ISOLATION

The output of the ACX is galvanically isolated from the chassis and input power. Output Neutral
to Chassis voltage is allowed to be 150 VAC, maximum. See paragraph 3.4, Output Power
Connection, for grounding information.
2.2

MECHANICAL SPECIFICATIONS

The ACX Power Source mechanical characteristics are:

2.2.1 DIMENSIONS AND WEIGHT

Parameter
Height:
Width:
Depth:
Weight:
Value
Notes
3.5" / 89 mm
2U rack mountable units
19.00" / 483 mm
Front panel with mounting brackets
16.75" / 426 mm
Main chassis
23.62" / 600 mm
Measured from back side of front panel, excludes
terminal blocks
40 lbs. / 18.2 kg
17
SECTION 2
SPECIFICATIONS