Output Power - Pacific 110ACX Operation Manual

Acx series
Table of Contents

Advertisement

SECTION 2
SPECIFICATIONS

2.1.2 OUTPUT POWER

OUTPUT VOLTAGE RANGE
The standard output voltage ranges of the ACX are:
0-150 Vac when operated in low range (FORM 1)
0-300 Vac when operated in high range (FORM 2)
OUTPUT CURRENT
FULL-RATED CURRENT
The full-rated output current of the ACX Power Source by model is:
Model
I
out, rms
110ACX
11 A
115ACX
16 A
118ACX
20 A
Refer to the Rating Curve charts of Figure 2.2 for maximum output current at a specific output
form, voltage, or power factor by model number.
OVERLOAD OPERATION
The ACX Power Source can deliver up to 120% of rated RMS output current at 25°C ambient
temperature with any input line voltage of 100 Vac or higher. However, total output power may
be limited by the AC input current limit at input voltage of 115V or less. Elevated ambient
temperature, low input voltage, or power factors between 0.8 and 1.0 will increase the internal
dissipation of the power source and can cause shutdown due to over-temperature conditions.
Length of time to reach over-temperature varies with the above parameters.
NOTE: All ACX Models are equipped with an over power protection feature. See section 4.10
for more details.
I
I
max, rms
out, pk
16.5 A
22 A
24 A
32 A
30 A
40 A
14
I
I
out, rms
max, rms
5.5 A
8 A
8 A
12 A
10 A
15 A
I
out, pk
11 A
16 A
20 A