-Dipswitch settings for each temperature on the computer board-
110 (T-KJr2) and 310 (T-K4) models
1 2 3 4 5 6 7 8
113 F
ON
(45
C)
OFF
510 (T-D2) models
1 2 3 4 5 6
104 F
ON
OFF
(40
C)
1 2 3 4 5 6
140 F
ON
OFF
(60 C)
110 (T-KJr2) and 310 (T-K4) models
Dipswitches
DO NOT set to 185 °F if you use your water heater in a recirculation
system. This will cause damage to the heater and void the warranty. (This
temperature setting is only available on the 510 (T-D2) models.)
WARNING
DO NOT adjust the left bank of dipswitches. For the 510 (T-D2) models.
Turn off the power supply to the water heater before changing the
dipswitch settings.
Only change the switches with the dark squares. The dark squares indicate
which direction the dipswitch should be set to.
Temperature Settings
122 F
1 2 3 4 5 6 7 8
ON
(50 C)
OFF
DEFAULT
Temperature Settings
1 2 3 4 5 6
1 2 3 4 5 6
113 F
113 F
ON
ON
OFF
OFF
(45 C)
(45 C)
1 2 3 4 5 6
158 F
ON
OFF
(70 C)
Location of the bank of dipswitches on the computer board
34
1 2 3 4 5 6 7 8
131 F
ON
(55
C)
OFF
<Right bank of dipswitches>
122 F
1 2 3 4 5 6
ON
(50 C)
OFF
DEFAULT
1 2 3 4 5 6
176 F
ON
OFF
(80 C)
Left bank of
dipswitches
7-Seg. LED
Right bank of
dipswitches
Page
Normal Operation
1 2 3 4 5 6 7 8
140 F
ON
(60
C)
OFF
1 2 3 4 5 6
131 F
ON
OFF
(55 C)
1 2 3 4 5 6
185 F
ON
OFF
(85 C)