Possible Cause
Possible Cause
myUTN User Manual Linux
A connection to the UTN server cannot be established
A common port will be used for the data transfer between the UTN
server and the SEH UTN Manager that is installed on the client.
52.
The port numbers are not identical.
The current port number cannot be transferred to the SEH UTN
Managers that are installed on the clients.
The 'SNMPv1' parameter has been disabled; see: 39.
The communication is blocked by a firewall.
A connection to the USB port cannot be established
The access control for USB devices is enabled 86.
No driver software for the USB device is installed on the client.
The USB port is already connected to another client.
A connection to the myUTN Control Center cannot be established
Eliminate possible error sources. First of all, check:
- the cabling connections
- the IP address of the UTN server 14 as well as
- the proxy settings of your browser
If you still cannot establish any connection, the following safety
mechanisms might be the cause:
The access is protected via SSL/TLS (HTTPS) 82.
The access is protected via SSL/TLS (HTTPS) and you deleted the
certificate (CA/self-signed/PKCS#12). Reset the parameter
values of the UTN server to their default settings to get access
111. Previous settings will be deleted.
The TCP port access control is enabled 83.
Appendix - Troubleshooting
142