4.5.5

Operation Check

After installation, execute the operation check with the self-diagnosis function.
Procedure
(a) Confirm that the "DSC watching" display appears.
The "DSC watching" display appears when the power is turned on. Almost all
Note
operations start from this display. This display also returns when each mode is closed.
MENU
(b) Press
The "MENU #1" display appears.
MENU
(c) Press
The "MENU #2" display appears.
(d) Select "4.Self test" and press
The "Self test" display appears.
(e) Select "1.Modem loop test" and press
The modem loop test starts.
(f) After 10 seconds, "OTHERS" LED blinks in the front panel. Press
MESSAGE" display appears.
62
DSC watching
06.Sep.2001(Thu) 01:26
N12'34 E123'45 SPEED:12.4KT at 01:26
Self-ID = 000000000
.
.
.
ENT
MODEM LOOP TEST
RECEIVED MESSAGE
RX date&time
: 06.Sep.2001(Thu) 01:26
Format
:INDIVIDUAL
Address
:xxxxxxxxx
Category
: ROUTINE
Telecommand-1
: J3E TEL
Telecommand-2
: NO INFORMATION
Work TX/RX freq : 12,346.5kHz/12,346.5kHz
End of sequence : EOS
Rx frequency
:
[UTC]
ENT
.
.
kHz
STOP
, the "RECEIVED