6. Remove the front panel of NCU-331/692.
7. Connect "RBK2" wire to NCU-331/692 terminal block No.6.
NCU-331/692
Terminal connection
To NQD-4190
Solder the "RBK2" wire to
unusing wire and insulate it
with vinyl tape.
"RBK2" wire
(7ZCJD0258 attached)
NQD-4190 Junction Box
Terminal number
8. Return the front panel of NCU-331/692.
9. Return the upper cover of NQD-4190.
10. Return the upper cover of NFC-296.
1
5
3
11. Return the shade cover and earth wire.
Replacing the CFG-296 Matching Unit in the NFC-296 is finished.