Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance 
Installation instructions
All local regulations including those referring to national and European standards 
·
must be observed when installing the appliance.
Ensure there is sufficient ventilation / air supply in the room from which your stove 
·
gets the combustion air. This is the room where the stove is installed if you do not 
use a wall or stove­base air­supply system.
The stove is not suitable for a shared flue system.
·
Ensure adequate access for cleaning the appliance, the flue gas connection and the 
·
chimney.
When installing the stove, take into account the minimum distances from the wall so 
·
as to avoid any fire risk. The minimum distances (sizes in cm) are shown in the 
figure below. 
Specifications Doran 
Nominal power of the stove is 10 kW. 
Flue gas mass flow = 7.5 g/s 
Appliance weight = 150 kg 
Minimum chimney draught = 8.0 Pa 
Flue gas temperature directly over the stove = 320 °C