Advertisement

Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance 
INSTRUCTIONS FOR INSTALLATION, 
USE AND MAINTENANCE
DORAN

Advertisement

Table of Contents
loading

Summary of Contents for Harrie Leenders DORAN

  • Page 1 Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  INSTRUCTIONS FOR INSTALLATION,  USE AND MAINTENANCE DORAN 1 ...
  • Page 2 Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance ...
  • Page 3: Table Of Contents

    Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  General instructions and regulations  Maintenance …………………………………………………………..  5  Service …………………………………………………………………  5  Declaration …………………………………………………………….  5  Characteristics report ………………………………………………...  5  Description of the Doran ………………………………………………  5  HETAS supplement  Health and Safety precautions …………..………………………….  6  Chimney ………………………………………………………………..  7  Hearth ………………………………………………………………….  8  Combustion air supply ………………………………………………..  8  Connection to chimney ……………………………………………..  8  Commissioning and handover ………………………………………  8  Manual What you should know about the Doran …………………………….  9  The three basic rules for proper burning …………………………..  9  Warning note ………………………………………………………….  10  Important notes ……………………………………………………….  10  User operating instructions ………………………………………….  11  The fine heat from wood ……………………………………………..  12  Initial fire­up, a good start ……………………………………………  12 ...
  • Page 4 Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  1.  Flue pipe  2.  Rotatable combustion chamber  3.  Glass / door  4.  Combustion chamber door  5.  Combustion chamber door handle  6.  Storage compartment door knob  7.  Storage compartment door 4 ...
  • Page 5: General Instructions And Regulations Maintenance

    Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  General instructions and regulations  Maintenance  Have the appliance serviced regularly by a qualified technician.  Ensure that the flue­gas connection and the chimney are cleaned regularly.  Check to ensure that the chimney is still open before lighting the stove again if it has not been  used for an extended period of time.  If, in spite of the precautions taken, there should occur a chimney fire (usually  accompanied by a roaring noise in the chimney), proceed as follows:  Shut off the air supply and close the door of the stove immediately  Call the fire brigade  Quickly extinguish the fire in the stove with sand  to prevent smoke from getting into your house  Ventilate the house  Never use water to extinguish the fire  Ensure that after a fire the chimney is first swept and inspected for any damage and leaks.  Service  It is not allowed to make any modifications to the appliance without prior authorization of the  manufacturer.  Only use replacement parts recommended by the manufacturer.  Declaration  The undersigned, representing the following:  Harrie Leenders Haardkachels, Industrieweg 25, 5688 DP, Oirschot, Nederland  herewith declare that the product Doran is in conformity with the provisions of the following EC  Directives when installed in accordance with the installation instructions contained in the product  documentation: EN 13240:2001/A2:2004 (E) "Roomheaters fired by solid fuel"  Product: Roomheaters fired by solid fuels as covered under the scope of this standard intended  use: Space heating in residential buildings.  Characteristics Report  Fire safety  2005PMC/12  Emission of combustion products  2005PMC/12  Release of dangerous substance  2005PMC/12  Surface temperature  2005PMC/12  Mechanical resistance (to carry a chimney / flue)  2005PMC/12  Thermal output / energy efficiency  2005PMC/12 ...
  • Page 6: Health And Safety Precautions

    Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  READ THE INSTRUCTION BOOKLET AND THESE SUPPLEMENTARY  INSTRUCTIONS CAREFULLY BEFORE INSTALLATION  These instructions together with those in the instruction booklet cover the basic principles  to ensure the satisfactory installation of the stove, although detail may need slight  modification to suit particular local site conditions.  In all cases the installation must comply with current Building Regulations, Local Authority  Byelaws and other specifications or regulations as they affect the installation of the stove.  It should be noted that the Building Regulations requirements may be met by adopting the  relevant recommendations given in British Standards BS 8303, BS EN 15287­1:2007 as an  alternative means to achieve an equivalent level of performance to that obtained following  the guidance given in Approved Document J.  Please note that it is a legal requirement under England and Wales Building Regulations  that the installation of the stove is either carried out under Local Authority Building  Control approval or is installed by a Competent Person registered with a Government  approved Competent Persons Scheme. HETAS Ltd operate such a Scheme and a listing of  their Registered Competent Persons can be found on their website at www.hetas.co.uk.  CO Alarms:­  Building regulations require that when ever a new or replacement fixed solid fuel or wood/  biomass appliance is installed in a dwelling a carbon monoxide alarm must be fitted in the  same room as the appliance. Further guidance on the installation of the carbon monoxide  alarm is available in BS EN 50292:2002 and from the alarm manufacturer’s instructions.  Provision of an alarm must not be considered a substitute for either installing the  appliance correctly or ensuring regular servicing and maintenance of the appliance and  chimney system.  HEALTH AND SAFETY PRECAUTIONS  Special care must be taken when installing the stove such that the requirements of the Health and Safety at  Work Act are met.  Handling  Adequate facilities must be available for loading, unloading and site handling.  Fire Cement  Some types of fire cement are caustic and should not be allowed to come into contact with the skin.  In  case of contact wash immediately with plenty of water.  Asbestos  This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of installa­  tion then please seek specialist guidance and use appropriate protective equipment.  Metal Parts  When installing or servicing this stove care should be taken to avoid the possibility of personal injury.  STOVE PERFORMANCE  Please refer to the table in the main instruction manual for details of the stoves’ performances...
  • Page 7: Chimney

    Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  PREPARATORY WORK AND SAFETY CHECKS  IMPORTANT WARNING  This stove must not be installed into a chimney that serves any other heating appliance.  There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit  fumes into the room.  Chimney  In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate  draught of approximately 15 Pa so as to clear the products of combustion and prevent smoke problems into  the room.  NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the  top of the chimney should be satisfactory. Alternatively the calculation procedure given in EN 13384­1 may  be used as the basis for deciding whether a particular chimney design will provide sufficient draught.  The outlet from the chimney should be above the roof of the building in accordance with the provisions of  Building Regulations Approved Document J.  If installation is into an existing chimney then it must be sound and have no cracks or other faults which  might allow fumes into the house. Older properties, especially, may have chimney faults or the cross sec­  tion may be too large i.e. more than 230 mm x 230 mm. Remedial action should be taken, if required, seek­  ing expert advice, if necessary. If it is found necessary to line the chimney then a flue liner suitable for solid  fuel must be used in accordance with Building Regulations Approved Document J.  Any existing chimney must be clear of obstruction and have been swept clean immediately before installa­  tion of the stove. If the stove is fitted in place of an open fire then the chimney should be swept one month  after installation to clear any soot falls which may have occurred due to the difference in combustion be­  tween the stove and the open fire.  If there is no existing chimney then any new system must be to the designation described above and in ac­  cordance with Building Regulations Approved Document J.  A single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for use as  the complete chimney. The chimney and connecting fluepipe must have a minimum diameter of 150 mm  and its dimension should be not less than the size of the outlet socket of the stove.  Any bend in the chimney or connecting fluepipe should not exceed 45°.  90° bends should not be used.  Combustible material should not be located where the heat dissipating through the walls of fireplaces or  flues could ignite it. Therefore when installing the stove in the presence of combustible materials due ac­  count must be taken of the guidance on the separation of combustible material given in Building Regula­  tions Approved Document J and also in these stove instructions.  If it is found that there is excessive draught in the chimney then a draught stabiliser should be fitted. Fitting  of a draught stabiliser will affect the requirement for the permanent air supply into the room in which the  stove is fitted in accordance with Approved Document J (see also combustion air supply).  Adequate provision e.g. easily accessible soot door or doors must be provided for sweeping the chimney  and connecting fluepipe where it is not intended for the chimney to be swept through the appliance. 7 ...
  • Page 8: Hearth

    Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  Hearth  The hearth should be able to accommodate the weight of the stove and its chimney if the chimney is not  independently supported. The weight of the stove is indicated in the brochure.  The stove should preferably be installed on a non­combustible hearth of a size and construction that is in  accordance with the provisions of the current Building Regulations Approved Document J.  The clearance distances to combustible material beneath, surrounding or upon the hearth and walls adja­  cent to the hearth should comply with the guidance on the separation of combustible material given in  Building Regulations Approved Document J and also in these stove instructions.  If the stove is to be installed on a combustible floor surface, it must be covered with a non­combustible ma­  terial at least 12mm thick, in accordance with Building Regulations Approved Document J, to a distance of  30 cm in front of the stove and 15 cm to each side measuring from the door of the combustion chamber.  Combustion air supply  In order for the stove to perform efficiently and safely there must be an adequate air supply into the room in  which the stove is installed to provide combustion air. The provision of air supply to the stove must be in  accordance with current Building Regulations Approved Document J. An opening window is not appropriate  for this purpose.  Connection to chimney  Stoves may have a choice of either a rear or top flue gas connector that allows connection to either a ma­  sonry chimney or a prefabricated factory made insulated metal chimney in accordance with their instruc­  tions. In some cases it may be necessary to fit an adaptor to increase the diameter of the flue to the mini­  mum required 150 mm section of the chimney or liner.  Commissioning and handover  Ensure all parts are fitted in accordance with the instructions.  On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out,  before lighting the stove. Once the stove is under fire check all seals for soundness and check that the flue  is functioning correctly and that all products of combustion are vented safely to atmosphere via the chimney  terminal.  On completion of the installation and commissioning ensure that the operating instructions for the stove are  left with the customer. Ensure to advise the customer on the correct use of the appliance and warn them to  use only the recommended fuel for the stove.  Advise the user what to do should smoke or fumes be emitted from the stove. The customer should be  warned to use a fireguard to BS 8423:2002 (Replaces BS 6539) in the presence of children, aged and/or  infirm persons. 8 ...
  • Page 9: Manual

    We  congratulate  you  on  the  purchase  of  your  stove.  This  manual  will  inform  you  about  the  best  way  of  using  the  stove  and  the  art  of  keeping  a  perfect  fire.  Before  using  the  stove, carefully read the text about breaking in the stove.  These  heating instructions  apply  to  the  Doran.  They  are  merely intended as  a  guideline  as your stove will behave differently according to the place where it is installed, simply  because the conditions are different. The flue, the weather, the quality of the wood used ...
  • Page 10: Warning Note

    Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  READ THE INSTRUCTION BOOK AND THESE INSTRUCTIONS CAREFULLY  BEFORE USING THE STOVE  WARNING NOTE  Properly installed, operated and maintained this stove will not emit fumes into the dwelling.  Occasional fumes  from de‑ashing and re‑fuelling may occur.  However, persistent fume emission is potentially dangerous and  must not be tolerated. If fume emission does persist, then the following immediate action should be taken:‑  (a)  Open doors and windows to ventilate the room and then leave the premises.  (b)  Let the fire go out.  (c)  Check for flue or chimney blockage and clean if required  (d)  Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected.  If necessary seek expert advice.  The most common cause of fume emission is flueway or chimney blockage. For your own safety these  must be kept clean at all times.  IMPORTANT NOTES  General  Before lighting the stove check with the installer that the installation work and commissioning checks de­  scribed above have been carried out correctly and that the chimney has been swept clean, is sound and  free from any obstructions. As part of the stoves’ commissioning and handover the installer should have  shown you how to operate the stove correctly.  CO Alarm  Your installer should have fitted a CO alarm in the same room as the appliance. If the alarm sounds unex­  pectedly, follow the instructions given under “Warning Note” above.  Use of fireguard  When using the stove in situations where children, aged and/or infirm persons are present a fireguard must  be used to prevent accidental contact with the stove.  The fireguard should be manufactured in accordance  with BS 8423:2002 (Replaces BS 6539).  Chimney cleaning  The chimney should be swept at least twice a year. It is important that the flue connection and chimney are  swept prior to lighting up after a prolonged shutdown period.  If the stove is fitted in place of an open fire then the chimney will require sweeping after a month of continuous  operation. This is a precaution to ensure that any “softer” deposits left from the open fire usage have not been  loosened by the higher flue temperatures generated by the closed stove.  In situations where it is not possible to sweep through the stove the installer will have provided alternative  means, such as a soot door.  After sweeping the chimney the stove flue outlet and the flue pipe connecting  the stove to the chimney must be cleaned with a flue brush.
  • Page 11: User Operating Instructions

    Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  Periods of Prolonged Non­Use  If the stove is to be left unused for a prolonged period of time then it should be given a thorough clean to  remove ash and unburned fuel residues. To enable a good flow of air through the appliance to reduce con­  densation and subsequent damage, leave the air controls fully open.  Extractor fan  There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit  smoke and fumes into the room.  Aerosol sprays  Do not use an aerosol spray on or near the stove when it is alight.  Use of operating tools  Always use the operating tools provided when handling parts likely to be hot when the stove is in use.  Chimney Fires  If the chimney is thoroughly and regularly swept, chimney fires should not occur.  However, if a chimney fire  does occur turn off the stove immediately and isolate the mains electricity supply (if applicable), and tightly  close the doors of the stove.  This should cause the chimney fire to go out. If the chimney fire does not go  out when the above action is taken then the fire brigade should be called immediately. Do not relight the  stove until the chimney and flueways have been cleaned and examined by a professional.  Permanent air vent  The stove requires a permanent and adequate air supply in order for it to operate safely and efficiently.  In accordance with current Building Regulations the installer may have fitted a permanent air supply vent  into the room in which the stove is installed to provide combustion air. This air vent should not under any  circumstances be shut off or sealed.  USER OPERATING INSTRUCTIONS  Recommended fuels  Stoves may be designed to burn dry seasoned wood logs and/or solid mineral fuel as indicated in the main  stove manuals.  HETAS Ltd Approval  HETAS approval may be limited to specific fuel types as detailed in the main instruction manuals. Approval  does not cover the use of other fuels either alone or mixed with the recommended fuel, nor does it cover  instructions for the use of other fuels. 11 ...
  • Page 12: The Fine Heat From Wood

    Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  Initial fire­up, a good start  You have purchased a brand­new stove, 'zero on the meter', has not seen a flame yet.  This means you are going to take care of the initial 'miles'. The ceramic firebricks will start  evaporating moisture and your wood­burning stove will start setting. For this reason, the  first few times, do not make your fire too hot because otherwise the bricks could crack.  You need not worry about any shrinkage cracks.  The initial fire­up requires some additional time and attention, as well as the approach we  have outlined below for you in steps. Before starting, please note the following important  points:  When starting the fire in the stove, open the aeration slide. (This is the kindling  position.)  You can properly control the fire with the aeration slide. The further the slide is  opened, the more vigorously your fire will burn.  Make sure there is sufficient ventilation. 12 ...
  • Page 13: Initial Fire­up In Steps

    Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  Initial fire­up in steps  1. Open the air slide completely by pulling it towards the front of the  stove. This is the kindling position.  2. Light a large ball of dry paper against the back plate of the burning  chamber and allow this fire to go out again.  3. Fill the stove with a handful of dry and thin kindling wood and light it.  When it burns properly, close the air slide a bit by pushing it  inwards. 4. Allow the fire to burn up and the stove to cool off for an hour so that  the moisture in the firebrick can evaporate. Some liquid might come  free from the ceramic fire­brick. Therefore place an old towel  underneath the stove before firing­up  5. After an hour, you will start bringing the entire stove to the proper  temperature using first some thin kindling wood.  Use the kindling position of the air slide until the fire burns  properly.  6. Then use thicker logs, ± 5x5 cm thick and 20 cm long. At the same  time, leave the aeration slide open. Close it a little bit when the fire is  burning properly.  13 ...
  • Page 14: How To Use The Doran

    Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  How to use the Doran  1. Fully open the air­control slide by moving it towards the front of the stove.  This is the kindling position.  2. Put 2 slightly larger logs on the bottom of the stove. Stack some  kindling wood on top of it. Stack lightly so that the flame can take hold.  Light the kindling wood up in the stove (at the top) with a firelighter or  some paper. Allow the Doran for a while to develop a good fire in order  to obtain a good draught and a proper fire at the bottom. This way, you  will also keep the flue cleaner. 3. When the fire gets smaller, add solid wood varying in thickness from  5 to 7cm. The amount depends on the heat required. Stack lightly.  Do not add more than 3 to 4 logs at a time. Be careful,  don't use the  kindling position of the air slide anymore.  4. After each loading, give the fire some extra oxygen by opening the  air slide a little bit until it is burning properly.  5. A quietly burning fire is obtained by closing the air slide even more  by pushing it inwards. This will reduce the draught in the Doran. For a  glowing mass of charcoal, you may close the air slide even further. The  heat will then last longer. When you want to let the fire die down, you  must open the air slide more.  14 ...
  • Page 15: The Power Of Fire

    Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  The power of fire  As a matter of fact just a few things withstand a real hot fire. Your fireplace can also be  damaged by overheating.  Just to prevent this, take account of not burning more than 3,5 kilograms of wood at the  same time. 3,5 Kilograms is approximately equal to 3,5 large logs; oak with 15%  moisture. The construction and the materials used from the fireplace are chosen to  control and resist a fire in a considered way. So heat with consideration.  A few tips  Make the fire always on a bed of ash. This is an insulating layer for the fire and an  excellent bed for the fuel.  If the Doran is overloaded with too much wood and the maximum amount of oxygen is  supplied (which happens when the air slide is fully open), the fire may 'run wild'. If this  should occur, close air slide by pushing it inwards. Never in such case leave the fireplace  unattended.  You also control the temperature by the amount and kind of fuel used for each load.  Remove excess ashes using a shovel or an ash cleaner. Never remove ashes using a  vacuum cleaner because fire may still continue to smoulder for days. Make sure you  leave a layer of ashes (± 3 cm) for the next fire to be made.  When the weather is foggy, pre­heat the flue prior to lighting your fire.. 15 ...
  • Page 16: Maintenance Ceramic Firebricks

    Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  Maintenance  Maintenance  Maintenance  1. Dust the stove using a non­fibrous cloth.  2. Damaged spots can be touched up using an abrasive cloth and  Harrie Leenders stove paint. Ask you supplier for advice  Maintenance ceramic firebricks  You need not worry about any cracks in the ceramic firebrick elements  as long as the flame does not come into direct contact with the metal  behind them. Glass  The glass can steam up when burning wet fuel or too little oxygen is  supplied. Also, the glass may steam up if the fire does not start fiercely  enough. This happens, for instance, when you start with small logs  instead of thin kindling wood. Moisture will then remain in the fireplace  for too long, and will settle on the coldest part: the glass.  Light moisture:  Use paper towel and then remove the light moisture using a damp cloth.  Counter pressure a little at the outside so that the glass panel does not  move.  Thicker deposits:  These can be treated with special fireplace­ glass cleaner (this can also  be done with a piece of moist paper towel and white ash). Allow a  moment for this to have its effect. Always make sure that these agents  do not come into contact with the painted surfaces in order to prevent  stains from being formed.  Moving parts  Moving and squeaking parts can be lubricated using graphite grease.  Ask your supplier for advice.  16 ...
  • Page 17: Collecting Soot When Sweeping The Chimney

    Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  Collecting soot when sweeping the chimney  1. Lift the heat shield a little and pull it towards the front. You can then  take it out easily.  2. Lift the steel deflector a little and push it towards the back. You can  then take it out easily.  3.   Put a newspaper on the bottom of the stove to collect the soot.  Close the door and the air­control slide.  4. After sweeping, place the deflector and heat shield back in their  positions. 17 ...
  • Page 18: Installation Instructions

    Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  Installation instructions All local regulations including those referring to national and European standards  · must be observed when installing the appliance. Ensure there is sufficient ventilation / air supply in the room from which your stove  · gets the combustion air. This is the room where the stove is installed if you do not  use a wall or stove­base air­supply system. The stove is not suitable for a shared flue system. · Ensure adequate access for cleaning the appliance, the flue gas connection and the  · chimney. When installing the stove, take into account the minimum distances from the wall so  · as to avoid any fire risk. The minimum distances (sizes in cm) are shown in the  figure below.  Specifications Doran  Nominal power of the stove is 10 kW.  Flue gas mass flow = 7.5 g/s  Appliance weight = 150 kg  Minimum chimney draught = 8.0 Pa  Flue gas temperature directly over the stove = 320 °C 18 ...
  • Page 19: General Instructions And Regulations

    Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  General instructions and regulations  The installation of the Doran with decorative casing must be carried out by a skilled  person employed by a dealer recognized by Harrie Leenders Haardkachels.  The casing parts are susceptible to scratching. Handle them gently.  After the stove has been properly installed, burn some kindling wood to check the  draught.  Please Note, the Doran has been tested by the manufacturers on a 3m straight flue.  Safety recommendations  Glass tends to break easily, and broken glass is quite sharp. Therefore take adequate  safety precautions.  For general safety, we refer to guidelines or regulations issued by a relevant official body  Materials and tools required Crosshead screwdriver · Box spanner set · Hexagonal wrench set · Masonry bits · Knife · Plumb line · Sliding pieces · Spirit level · Sack truck · Single walled flue pipe and accessories  · Materials included Top plate with or without a hole for top or rear outlet · Right angled bend ( rear outlet only ) · 4 self tapping screws 3.5 x 9.5 ( +2 spares ) ·...
  • Page 20 Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  1. Removing the packaging material  2. Moving the stove  Carefully remove the packaging material (without  Put a cushion or blanket between the sack truck  damaging the paint). Leave plastic cover wrapped  and the stove.  around the stove.  Place the stove on the sacktruck, its left side  Open the lower door and unscrew the stove from  resting against the sack truck.  the pallet.  Caution: not the side of the door!  Then, push the loose bolts out of the pallet.  Then move the stove to the place of installation  desired.  3. Positioning the stove  When air is supplied through the floor or wall, first  4. Installing duct material on top outlet  take the appropriate measures.  First place the top plate on the top head.  See instructions below.  Fix the wall or ceiling plate (if applicable).  Place the sliding pieces under the feet of the stove  Connect the duct material.  (4x). Carefully push the stove in its correct position.  Allow for the minimum distance to flammable  materials.  Then remove the plastic protective cover and the  sliding pieces. 20 ...
  • Page 21 Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  5. Installing the flue for rear outlet  6.  Release the lower transport lock bolts  Secure the wall plate (if applicable).  Open the small door in the base.  Connect the flue pipe  Remove the red bolts (open­end spanner ).  Loosen the green bolts up to the stop, then secure  them (open­end spanner ).  7. Release the upper transport lock bolts  8. Levelling  Remove the 4 red bolts (open­end spanner ).  Open the small door in the base.  Use the adjusting feet to level the stove.  Position the level as shown in the picture. 21 ...
  • Page 22 Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  9. Placing the front panel for stove with top outlet  10. Adjusting the front panel for stove with top outlet  Position the front panel against the top plate.  The fasteners at the top become accessible by  Be careful not to cause any damage: first place  turning the top plate carefully to the left and then to  the upper part, then the lower part against it.  the right (without damaging the paint). The fasteners  at the bottom become accessible by turning the  stove.  Fix the front panel using 4 countersunk M6 screws  (no. 1)  Use the four adjusting screws (no. 2) to adjust the  height of the front panel so as to be equal to the  surrounding decorative part.  Firmly tighten the countersunk screws (no. 1).  Then place the top plate properly in the centre. 22 ...
  • Page 23 Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  12. Adjusting the front panel for stove with rear outlet  11. Placing the front panel for stove with rear outlet  The fasteners at the bottom become accessible by  Position the front panel against the top head.  Be careful not to cause any damage: first place the  turning the stove.  Fix the front panel using 4 countersunk M6 screws  upper part, then the lower part against it.  (no. 1).  Use the four adjusting screws (no. 2) to adjust the  height of the front panel so as to be equal to the  surrounding decorative part.  Firmly tighten the countersunk screws (no. 1).  Then place the top plate on the stove.  13. Air supplied through floor or wall  Open the small door in the base.  Place the cover plate in the base against the hole of  the air supply box.  Fix the cover plate using the four socket­head  screws.  Cut the air pipe to length. 23 ...
  • Page 24 Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance ...
  • Page 25 Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance ...
  • Page 26 Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance  U K Distributor.  Robeys Ltd.  Riverside, Goods Road, Belper,  Derbyshire, England.  DE56 1UU  Tel: 01773 820940  Fax: 01773 820477  E Mail: info@robeys.co.uk  www.robeys.co.uk  26  June 2011...

Table of Contents