Warning Note; Important Notes - Harrie Leenders DORAN Instructions For Installation Manual

Table of Contents

Advertisement

Harrie Leenders Doran ­ Instructions for Installation, Use and Maintenance 
READ THE INSTRUCTION BOOK AND THESE INSTRUCTIONS CAREFULLY 
BEFORE USING THE STOVE 
WARNING NOTE 
Properly installed, operated and maintained this stove will not emit fumes into the dwelling.  Occasional fumes 
from de‑ashing and re‑fuelling may occur.  However, persistent fume emission is potentially dangerous and 
must not be tolerated. If fume emission does persist, then the following immediate action should be taken:‑ 
(a)  Open doors and windows to ventilate the room and then leave the premises. 
(b)  Let the fire go out. 
(c)  Check for flue or chimney blockage and clean if required 
(d)  Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected. 
If necessary seek expert advice. 
The most common cause of fume emission is flueway or chimney blockage. For your own safety these 
must be kept clean at all times. 
IMPORTANT NOTES 
General 
Before lighting the stove check with the installer that the installation work and commissioning checks de­ 
scribed above have been carried out correctly and that the chimney has been swept clean, is sound and 
free from any obstructions. As part of the stoves' commissioning and handover the installer should have 
shown you how to operate the stove correctly. 
CO Alarm 
Your installer should have fitted a CO alarm in the same room as the appliance. If the alarm sounds unex­ 
pectedly, follow the instructions given under "Warning Note" above. 
Use of fireguard 
When using the stove in situations where children, aged and/or infirm persons are present a fireguard must 
be used to prevent accidental contact with the stove.  The fireguard should be manufactured in accordance 
with BS 8423:2002 (Replaces BS 6539). 
Chimney cleaning 
The chimney should be swept at least twice a year. It is important that the flue connection and chimney are 
swept prior to lighting up after a prolonged shutdown period. 
If the stove is fitted in place of an open fire then the chimney will require sweeping after a month of continuous 
operation. This is a precaution to ensure that any "softer" deposits left from the open fire usage have not been 
loosened by the higher flue temperatures generated by the closed stove. 
In situations where it is not possible to sweep through the stove the installer will have provided alternative 
means, such as a soot door.  After sweeping the chimney the stove flue outlet and the flue pipe connecting 
the stove to the chimney must be cleaned with a flue brush.