Cylinder Connections - Rinnai SG2152HP Installation Manual

Rinnai sg2152hp solar split system, hotflo glass lined tank, e-frost collector, gas and electric boost
Table of Contents

Advertisement

Cylinder connections

Pressure
limiting valve
Cold water
pressure relief
valve
temperature
& pressure
relief valve
(tPr)
Drain valve
Provision must be made to drain the cylinder if required for servicing.
Drain lines
These must be installed in accordance with aS3500 and or G12/aS1. G12 is
available online at no cost from:
www.dbh.govt.nz/building-code-compliance-documents
tempering
during times of high solar gain water temperatures in solar systems can
valve
become very high. a tempering valve will be required. Ensure that it is
suitable for use with solar systems. many suppliers have a dedicated solar
range to handle the higher temperatures.
rinnai new Zealand Limited
rinnai Glass Lined 180 litre
rinnai Glass Lined 270 and 340 litre
rinnai Glass Lined 180 litre
rinnai Glass Lined 270 and 340 litre
rinnai Glass Lined 180 litre
rinnai Glass Lined 270 and 340 litre
- 700 kPa
- 500 kPa
- 850 kPa approximately
- 700 kPa approximately
- 1000 kPa
- 850 kPa
10
[supplied with cylinder]
[supplied with cylinder]
E-Frost Solar Collector Split System
install manual: 11497-a