Step 8: Install Appropriate Electrical Plug - Jim Chookagian NF3L Installation & Operation Manual

Frontload washers
Table of Contents

Advertisement

Installation

Step 8: Install Appropriate Electrical Plug

400 Volt, 50 Hertz, 9.8 Amp
NOTE: This washer is factory-wired for a 400 Volt
electrical supply.
Have a qualified electrician install appropriate
electrical receptacle.
To attach customer-supplied power cord
(400 Volt WYE):
1. Remove electrical access panel on rear of
machine.
2. Remove plastic plug from hole in rear of
machine.
3. Install strain relief, supplied with machine, in
hole.
4. Put power cord through hole. Refer to Figure 12.
1
Install power cord through this hole after
removing plastic plug. Use strain relief
supplied in accessories bag.
Figure 12
5. Attach power cord wires as shown in Figure 13.
6. Tighten down the strain relief (supplied with
unit) on the power cord.
7. Reinstall access panel.
14
1
FLW1953N
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
1
2
3
L 1 L 2 L 3
400
Volt
400
Volt
400
Volt
230
Volt
TERMINAL BLOCK WIRED FOR 400 VOLT WYE
AS VIEWED THROUGH REAR ACCESS PANEL
2
NOTE: 1.5 mm
wire required for 3 phase, 4 wire
connection.
1
Black Wire
2
Black/White Wire
3
Black/Red Wire
4
White Wire
5
White/Red Wire
6
White/Black Wire
7
Green/Yellow Wire
8
Earth – Power Cord
Figure 13
4
5
6
7
N
230
Volt
8
230
Volt
FLW1915N
803623 (EN)

Advertisement

Table of Contents
loading

Table of Contents