Electrical Requirements; Tools Needed For Assembly - Emerson CF144BS00 Owner's Manual

Curva sky 44” & 52” damp & wet location snugger ceiling fan
Hide thumbs Also See for CF144BS00:
Table of Contents

Advertisement

THE FAN MODELS CF144BS, CF144CRM, CF152BS & CF152CRM ARE
SUITABLE FOR DAMP LOCATIONS SUCH AS COVERED PORCHES, COVERED
PATIOS, AND COVERED DECKS...ANYWHERE THERE IS A ROOF OVERHEAD.
THE FAN MODELS CF144WW, CF144ORB, CF152WW & CF152ORB ARE
SUITABLE FOR WET LOCATIONS SUCH AS PORCHES, PATIOS, AND DECKS.
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,

Tools Needed for Assembly

One Phillips head screwdriver
One wire stripper
Materials
Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would be
a 3-conductor (2-wire with ground) of following size:
Installed Wire Length
Up to 50 ft.
50-100 ft.
IMPORTANT: Your ceiling fan will not function
properly, and may be damaged, if used with any
wall dimmer switch or control other than the
Emerson Electric Fan/Light Remote Control
supplied with the fan.
Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capable
of withstanding a load of at least 50 pounds.
WARNING
!
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked "Acceptable for
Fan Support of 22.7 kg. (50 lbs.) or less", and use
screws supplied with outlet box. Most outlet boxes
commonly used for support of light fixtures are not
acceptable for fan support and may need to be
replaced. Consult a qualified electrician if in doubt.
Install, Operate and Maintain Your Ceiling Fan
One stepladder
Wire Size A.W.G.
14
12

Electrical Requirements

!
Before assembling your ceiling fan, refer to section on
proper method of wiring your fan (page 7). If you feel
you do not have enough wiring knowledge or
experience, have your fan installed by a licensed
electrician.
If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time and
remove the existing light fixture.
!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring must
be in accordance with National and Local codes and
the ceiling fan must be properly grounded as a
precaution against possible electrical shock.
!
To avoid fire or shock, follow all wiring instructions
carefully.
Any electrical work not described in these
instructions should be done or approved by a licensed
electrician.
4
WARNING
WARNING
WARNING
U.L. Model No.: CF144 & CF152