BIG ASS FANS Haiku 60 Installation Manual page 17

Table of Contents

Advertisement

Wiring diagram (with terminal strip)
Ensure power is disconnected before installing the fan!
Do not use the fan with a dimmer switch.
WARNING: Do not connect the fan to a damaged power source! Do not attempt to resolve
electrical failures on your own. Consult a qualified electrician if uncertain of the electrical
installation of this fan.
Wire color chart
50/60 Hz Compatible
Fan Power Supply
Wire Color
Southeast Asia
220–240V System
Switched 220–240VAC 1 ,
50Hz, 0.36A
HAIKU
®
by Big Ass Fans
AC Line (L1)
AC Line/Neutral (L2/N)
Brown
Brown, Black, or Grey
(connected to fan chassis)
Blue
Green with Yellow Tracer
Blue
Green with Yellow Tracer
PE/Earth Ground
AC Neutral / L2
AC Hot / L1
ELECTRICAL (CONT.)
Earth/PE
13