Rugby 620, Technical Data

Technical Data

Conformity to National Regulations

For products which do not fall under R&TTE directive:
Hereby, Leica Geosystems AG, declares that the product/s is/are in
compliance with the essential requirements and other relevant provi-
sions of the applicable European Directives. The declaration of
conformity can be consulted at http://www.leica-geosystems.com/ce.

General Technical Data of the Laser

Operating range (diameter):
Rugby 620:
Self-levelling accuracy:
Self-levelling accuracy is defined at 25°C (77°F)
Self-levelling range:
Rotation speed:
239 mm (9.4")
005797_001
Rugby 620 weight with battery:
Type
A600 Lithium-Ion (Li-Ion Pack)
Alkaline (four D-cells)
*Operating times are dependent upon environmental conditions.
Charging the Li-Ion battery pack takes a maximum of five hours.
Use only high quality alkaline batteries to achieve operating time.
800 m/2600 ft
±1.5 mm at 30 m (±1/16" at 100 ft)
±5°
10 rps
192 mm (7.6")
2.56 kg/5.6 lbs.
Operating times* at 20°C
40 h
60 h