NEC PlasmaSync 50MP1 User Manual page 68

Multimedia monitor
Hide thumbs Also See for PlasmaSync 50MP1:
Table of Contents

Advertisement

(2) Flashing in red (Temperature error detected)
Is the potential 0V at Pin 10
of IC9806 (MAIN PWB)?
YES
Are TH1 in the POWER unit
and its peripheral circuits out
of order?
(Caution) How to reset the alarm:
• Turn the power circuit off and on at the main power supply, remote control, or the wall outlet.
(3) Reciprocally flashing in green and red (Cracks in the panel detected)
Is the potential 0V at Pin 100
of IC9501 (MAIN PWB)?
YES
Is the potential 0V at Pin 2 of
IC9505 (MAIN PWB)?
YES
Failure in the periphery of the
PDP module circuit.
(Caution) How to reset the alarm:
• Turn the power circuit [ON], with the input changeover key of the product kept pressed. In this state,
keep on pressing the input changeover key for more than 2 seconds.
NO
Is 5V available at Pins 13 to
15 of IC9806?
Is 5V available at Pin PN3?
IC9806 or IC9501 and its
peripheral circuits are out of
order.
NO
IC9501 and peripheral circuits
are out of order.
NO
Is 5V available at Pin 14 of
IC9505?
A
Go to 1-1. "No power available" (P. 2).
4
YES
NO
NO
YES
YES
NO
IC9806 or IC9806 and
peripheral circuits are out
of order.
Failure in the POWER unit
or in another IC that uses
A+5V.
IC9505 and peripheral cir-
cuits are out of order.

Advertisement

Table of Contents
loading

Table of Contents