21. Stick one each of the insulation seats M68 to the parts mounting
sides of the SENS PWB A04 and the SENT PWB A05, respec-
tively.
22. Stick two insulation seats to each of the two plates M48. Apply
Hole A of the SENS PWB and also that of the SENT PWB to Hole
A of the plate, and tighten them together by the use of the one
screw SRW39, respectively.
23. Mount the plate, attached to the SENS PWB and also to the SENT
PWB, on the main body by the use of the one screw SRW40,
respectively.
M48
TOP
A04
TOP
SRW40
A04,05
A
FRONT
M68 x 3
M48 x 2
SRW39
SRW40
A05
SRW39
6