Start The Engine - Volvo Penta IPS User Manual

Table of Contents

Advertisement

Starting
P0012497
58
0

Start the engine

If a station is locked the engines can only be started
and stopped from this station.
Start using the ignition switch
Turn the key for each engine to position III. Release
the key and let it spring back to position I as soon as
the engine has started.
If repeated start attempts are needed, the key must be
turned back to position 0 first.
Starting with the starter button
Press the starter button for each engine. Release the
button as soon as the engine has started.
If you start from a secondary station, the starter key at
the main control station must be in position I.
Overheating protection
If the starter motor is engaged for its maximum activa-
tion time (30 seconds), the starter motor circuit is cut
automatically to protect the starter motor from over-
heating. If possible, leave the starter motor to cool for
at least five minutes before making a new start attempt.
Read the instruments and warm the
engine up
Allow the engines to idle for the first ten seconds.
Check that instruments and warning displays show
normal values.
Check that no messages are displayed and no warning
signs are showing. If a fault is registred, please refer
to section Fault Handling page 67 for further infor-
mation and recomended actions.
Warm the engine up at low speed and low load, so
normal operating temperature is reached before full
power is used.
IMPORTANT!
Never race the engine when it is cold.
47705796 05-2014 © AB VOLVO PENTA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents