Change the "OFF" time with the U U P P or D D O O W W N N Scroll Keys.
Switch to previous menu item with Radio Button I I .
Switch to next menu item with Radio Button I I I I .
6 6 . . 1 1 . . 3 3 T T e e m m p p e e r r a a t t u u r r e e O O f f f f s s e e t t
The actual soldering tip temperature can be changed
±72°F/±40°C by the input of a temperature offset. The
Offset function is used to match the station display to
the tip temperature when measured with an external
instrument.
Change the "Offset" value with the U U P P or D D O O W W N N Scroll
Key.
Switch to previous menu item with Radio Button I I .
Switch to next menu item with Radio Button I I I I .
6 6 . . 1 1 . . 4 4 S S e e t t b b a a c c k k T T i i m m e e
If the soldering tool is not being used, the temperature
is decreased automatically to Standby temperature (see
6.1.1) after the specified Setback time has elapsed. The
Setback time, after which the soldering unit switches
to Standby mode, can be set from 0 – 99 minutes. With
a setting of "0 min", the Setback function is switched
Off. The Setback status is indicated by a flashing
"Read" temperature and "S S T T A A N N D D B B Y Y " appears in the
display. Depress the U U P P or D D O O W W N N Scroll Key to end
"Setback" and return the station to the "Set" tempera-
ture.
Change the "Setback" time with the U U P P or D D O O W W N N Scroll
Key.
Switch to previous menu item with Radio Button I I .
Switch to next menu item with Radio Button I I I I .
6 6
6 6 . . 1 1 . . 5 5 W W i i n n d d o o w w F F u u n n c c t t i i o o n n
The Window Function allows the temperature to be
adjusted within a range (max. ±180 °F. (±99 °C )), above
and below the Locked temperature (see65.1.7). The
Locked temperature thus represents the middle of the
settable temperature range.
Note: To utilize the window function, the station has to
first be placed into Lock mode.
Use the U U P P / D D O O W W N N Scroll Keys to change the range of
temperatures allowed witin the operating "window".
Switch to previous menu item with Radio Button I I . .
Switch to next menu item with Radio Button I I I I .
6 6 . . 1 1 . . 6 6 S S w w i i t t c c h h i i n n g g T T e e m m p p e e r r a a t t u u r r e e S S c c a a l l e e s s ° ° F F / / ° ° C C
Use the UP or DOWN Scroll Key to switch between ° ° F F
and ° ° C C and vice versa.
Switch to previous menu item with Radio Button I I .
Switch to next menu item with Radio Button I I I I .