Winterize And Long Term Storage - Homeright Power-Flo Pro 2800 Instruction Manual

1/2 hp airless
Table of Contents

Advertisement

Available languages

Available languages

WINTERIZE AND LONG TERM STORAGE

FOR POWER-FLO PRO PUMP
• Remove the inlet hose from inlet port, leave bypass hose on with unit upright.
• Use pen or pencil to push inlet ball up so cleaning solution drains from unit. (Figure T)
• Flip unit upside down and add 1/3 of the oil supplied to inlet port. (Figure U)
• Wait 30 seconds and flip unit back onto its feet.
• Be careful to block discharge port and inlet port with paper towel as some oil
will splatter out and could get in eyes or on clothing.
• Turn prime/spray switch to PRIME Cycle unit on and off 3 times with power switch to run
oil into unit.
• Turn prime/spray switch to SPRAY. Cycle unit on and off 3 times. (Figure V)
• Ensure inlet and bypass hose are drained.
• Unit is ready for storage.
FOR THE GUN AND HOSE
• Remove high pressure hose from unit and gun from hose.
• Remove nozzle and guard from gun.
• Hold gun upside down and add 20 drops of oil to inlet of gun.
• While holding gun upside down, pull trigger to allow oil to run into gun.
• Lay hose flat and lift one end to drain hose or use a compressor regulated to
5 PSI to blow cleaning solution out of hose.
• Coil hose and gun/hose is ready for storage.
ALTERNATE METHOD
• Submerge suction tube into RV antifreeze (DO NOT USE AUTOMOTIVE ANTI-FREEZE).
• Remove spray tip/guard from spray gun, turn Prime/Spray switch to Prime, trun Power
Switch ON. When antifreeze comes out of return tube, turn Prime/Spray switch to SPRAY
and trigger spray gun into waste pail.* (Figure W)
• Run until pink RV antifreeze comes out of spray gun.
• This will protect and lubricate down to -50° F.
* Check with local codes for proper disposal.
800879 POWER-FLO
PRO 2800
®
14
T
U
V
W
ENGLISH

Hide quick links: