27. Diagnostics

Diagnostic LEDs

The controller is fitted with diagnostic lights (LEDs) that assist with the setup and
maintenance of the gate.
Figure 82 below provides the description and purpose of the indicator lights also
indicating the location on the controller

Gate Status LED Indication

Slow regular flash
Fast regular flash
One flash every two seconds
Two flashes every two seconds
Three flashes every two seconds
Four flashes every two seconds
Four flashes every two seconds
FIGURE 83.
Gate is opening
Gate is closing
Courtesy Light latched on
Mains Failure
Battery-low
Collision Shutdown
Multiple Collisions have occurred
Page 72
Safe CLS (Safety Closing Beam)
On when the closing beam is not activated
Off when closing safeties obstructed
Safe OPN (Safety Opening Beam)
On when the opening beam is not activated
Off when opening safeties obstructed
LCK/STP
On when system ready to operate
Off when system locked
TRG
On when the trigger signal is present
Off when no signal
PED
On when the pedestrian signal is present
Off when no signal
FRX
On when a free-exit signal is present
Off when no signal
LIT
On when signal present
Off when no signal
LED
On when gate open
Off when gate closed