Defining Criteria - Motorola MC32N0 Integrator Manual

Hide thumbs Also See for MC32N0:
Table of Contents

Advertisement

Defining Criteria

Procedure:
1 Touch Criteria.
Figure 70: Criteria Screen
2 Touch String to check for option to specify the string that must be present in the data.
3 In the Enter the string to check for dialog box, enter the string
4 Touch Done.
5 Touch OK.
6 Touch String position option to specify the position of the string specified in the String to check for option. The
ADF rule is only applied if the specific string in String to check for is found at the specified String position
location (zero for the start of the string).
7 Touch the + or - to change the value.
8 Touch OK.
9 Touch String length option to specify a length for the received data. The ADF rule only applies to the bar code
data with that specified length.
10 Touch the + or - to change the value.
11 Touch OK.
12 Touch Source criteria option to associate an input device to an ADF rule. The ADF rule only applies to data
received from associated input devices.
13 Touch Barcode input.
14 Touch the Source enabled checkbox to accept data from this source.
Figure 71: Barcode Input Screen
DataWedge Configuration | 77