Table Of Contents; Before Installation - Daikin FXFQ20AVEB Installation And Operation Manual

Vrv system air conditioners
Hide thumbs Also See for FXFQ20AVEB:
Table of Contents

Advertisement

FXFQ20AVEB
FXFQ40AVEB
FXFQ25AVEB
FXFQ50AVEB
FXFQ32AVEB
FXFQ63AVEB
C
ONTENTS
Before installation.............................................................................. 1
Selecting installation site................................................................... 2
Preparations before installation......................................................... 3
Indoor unit installation ....................................................................... 4
Refrigerant piping work ..................................................................... 4
Drain piping work .............................................................................. 5
Electric wiring work ........................................................................... 6
Wiring example ................................................................................. 8
Installation of the decoration panel ................................................... 8
Field setting....................................................................................... 8
Test operation.................................................................................... 9
Maintenance...................................................................................... 9
Disposal requirements .................................................................... 10
Wiring diagram ................................................................................ 11
READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.
IMPROPER
INSTALLATION
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES, OPTIONAL EQUIPMENT AND
SPARE
PARTS
MADE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.
IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR ADVICE
AND INFORMATION.
The English text is the original instruction. Other languages are
translations of the original instructions.
B
EFORE INSTALLATION
Leave the unit inside its packaging until you reach the
installation site. Where unpacking is unavoidable, use a sling of
soft material or protective plates together with a rope when
lifting, this to avoid damage or scratches to the unit.
Refer to the installation manual of the outdoor unit for items not
described in this manual.
Caution concerning refrigerant series R410A:
The connectable outdoor units must be designed exclusively for
R410A.
Do not place objects in direct proximity of the outdoor unit and
do not let leaves and other debris accumulate around the unit.
Leaves are a hotbed for small animals which can enter the unit.
Once in the unit, such animals can cause malfunctions, smoke
or fire when making contact with electrical parts.
Installation and operation manual
1
FXFQ80AVEB
VRV System air conditioners
FXFQ100AVEB
FXFQ125AVEB
Page
OR
ATTACHMENT
OF
BY
DAIKIN
WHICH
ARE
Precautions
This appliance is not intended for use by persons, including
children, with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure that they do not play
with the appliance.
This appliance is intended to be used by expert or trained users
in shops, in light industry and on farms, or for commercial use by
lay persons.
Do not install or operate the unit in rooms mentioned below.
Places with mineral oil, or filled with oil vapour or spray like in
kitchens. (Plastic parts may deteriorate.)
Where corrosive gas like sulphurous gas exists. (Copper tubing
and brazed spots may corrode.)
Where volatile flammable gas like thinner or gasoline is used.
Where machines generating electromagnetic waves exist.
(Control system may malfunction.)
Where the air contains high levels of salt such as air near the
ocean and where voltage fluctuates a lot (e.g. in factories). Also
in vehicles or vessels.
When selecting the installation site, use the supplied paper
pattern for installation.
Do not install accessories on the casing directly. Drilling holes in the
casing may damage electrical wires and consequently cause fire.
Sound pressure level is less than 70 dB(A).
Accessories
Check if the following accessories are included with your unit.
1
2
3
1x
1x
8x
8
9
10
1x
1x
1x
1
Metal clamp
2
Drain hose
3
Washer for hanger bracket
4
Screw
5
Installation guide
6
Installation and operation manual
7
Insulation for fitting for gas pipe
8
Insulation for fitting for liquid pipe
9
Large sealing pad
10
Medium 1 sealing pad
11
Medium 2 sealing pad
12
Small sealing pad
13
Drain sealing pad
14
Paper pattern for installation (upper part of packing)
15
Clamp
Installation
and operation manual
4
5
6
4x
1x
1x
11
12
13
14
1x
1x
1x
1x
FXFQ20~125AVEB
VRV System air conditioners
3P320142-1A - 2012.10
7
1x
15
7x

Hide quick links: