CODE
DESCRIPTION
E003
Electronics too hot
E005
Communication error
E009
ROM check error in user interface
E010
Data memory error in user interface
E011
Continuous pushing of single key
E012
Defective User Interface PCB temp.
sensor
E014
ON/OFF key does not work
E032
Continuous pushing of keys
E101/E201
Cvt 1/Cvt 2 Temp. sensor open
E104/E204
Cvt 1/Cvt 2/Temp. sensor shorted
E106/E206
Cvt 1/Cvt 2 Door latch does not lock
E107/E207
Cvt 1/Cvt 2 Door latch does not
unlock
E115/E215
Cvt 1/Cvt 2 Temp. in unlocked cavity
too high
E116
Cvt 1/Cvt 2 Probe error
E118/E218
Cvt 1/Cvt 2 Cooling fan supervision
error
E122
Cvt 1/ Probe sensor temp. too high
E123
Cvt 1/ Probe sensor temp. too low
E124/E224
Cvt 1/Cvt 2 Door switch error
E126/E226
Cvt 1/Cvt 2 Door latch error
E303
Electronics too hot
E309
ROM Check error in control module
E310
Data memory error in control module
CAUSE/ACTION
User interface exceeds
185°F/85°C
Loss of communication
between user interface and
control module. Start-up
error. Check connection of all
communication lines and
control module inputs.
Check user interface
assembly. Inspect touch
PCB.
10 seconds of multiple keys
being pressed.
Refer to Diagram 2/4
Refer to Diagram 2/4
Refer to Diagram 2/4
Refer to Diagram 2/4
Standard probe module is
part of the control module.
Refer to Diagram 1.
Cooling fan speed is too low
or too high. Refer to Diagram
2/4.
Door switch is in undefined
state. Refer to Diagram 2/4.
Door latch is in an undefined
state. Refer to Diagram 2/4.
Control module exceeds
212°F/100°C.
Service Manual for Thermador Professional Series Built-in Wall Ovens
CODE
DESCRIPTION
E312
Defective control module PCB temp.
sensor
Table 8 Error codes
6

SERVICE MODE

Only the PODx models with a display have Service Mode capabilities.
1. Set oven mode knob(s) to OFF.
2. Set upper oven temperature knob to 100°.
3. Press SELECT,
, and
(P5.1 will appear in the display.)
A button press or change in mode knob will prompt a response.
Service mode will terminate when the upper oven temperature knob is
turned, an oven cavity exceeds 400°, or when idle time exceeds 5
minutes.
7

OPTION CODE

The Option Code on Pro Series ovens is programmed in memory and
will automatically transfer to the User Interface board and PC Control
Module when necessary. Option Codes are provided in Table 9 for
information purposes only.
MODEL
OPTION CODE
PO301
0550
POD301
0551
PODC302
1251
POMW301
0550
Table 9 Option codes
CAUSE/ACTION
simultaneously for 5 seconds.
MODEL
OPTION CODE
PO302
1050
POD302
1051
POM301
0550