4.15

Rotisserie Motor

If the rotisserie does not turn with the door closed and the oven in a
rotisserie mode, replace the rotisserie motor (120V 12W).
The maximum weight allowed on the rotisserie spit is 12 lbs.
5

ERROR CODES

A Service Guide with error code information, wiring diagrams, and
instructions for entering Service Mode (if applicable) is packed with
every unit. Find it on the underside of the upper plenum access panel
as shown in Figure 19.
Figure 19 Location of Thermador Built-in Oven Service Guide
5.1
How Error Codes are Communicated
On models without a digital display, error codes are communicated
through a series of 3 LEDs on the User Interface (see Figure 20)
blinking at a frequency of .5 seconds on and .5 seconds off.
1
3
2
Figure 20 LEDs used to communicate error codes on the PO301 user interface (left)
and PO302 user interface (right)
1
2
3
Service Manual for Thermador Professional Series Built-in Wall Ovens
LED1 communicates the left digit of the error code.
LED2 communicates the middle digit of the error code.
LED3 communicates the right digit of the error code.
For example, Error Code 115 is displayed by 1 blink of LED1, 1 blink
of LED2, and 5 blinks of LED3. After a 1 second pause, the end of the
code series will be signaled by LED1, LED2, and LED3 turning on for
1 second. The sequence will then repeat.
On models with digital display, digital error codes will show to the right
of the clock (see Figure 21), and blink at a frequency of 2 seconds on,
.5 second off. Clear the error by touching the + and – buttons
simultaneously.
E115
Figure 21 Error code 115 displayed on POD302/PODC302 user interface
5.2

Error Code Table

The following table is included in the PO302/POD302/PODC302
Service Guide. (The same error code information applies to
PO301/POD301/POM301/POMW301 models except for the E2xx
codes, which only apply to models with 2 cavities.)
Diagrams referenced in the table can be found in the appropriate
Service Guide.
CODE
DESCRIPTION
E000
Wrong module combination
TOUCH TO CLEAR ERROR
CAUSE/ACTION
Control module and user
interface are mismatched. Set
Option Code properly.