PLUG NO
PIN NO
4-RD
5-BK
6-WH
X209
1-BU/WH
2-BU
* POD models only
** PODC only
Table 7 Plugs and pins on the PC control module
To remove the PC Control Module:
1. Disconnect all wires.
2. Remove 1 T20 screw securing control module to chassis.
3. Slide module to the left to release the 3 tabs on the bottom of
the module bracket from the 3 slots in the chassis.
Always reset the oven and test after changing the control module. In
some cases, a second reset may be necessary.
4.10
Power Supply Module
The power supply module (9.6V 12.5W) provides DC voltage to the
control module and user interface.
4.11
Halogen Light Transformer(s)
One transformer (120V-12V 40VA) is utilized per cavity. Triac
switches 120 VAC to the transformer. There are 4 terminals on the
new transformer, as shown in Figure 17.
The resistance between the primary terminals should measure ~12.8
ohms and the resistance between the secondary terminals should
measure ~0.32 ohms.
FROM/TO
Hall Effect Sensor
Hall Effect Sensor
Temperature Sensor
X105-P3 to Cooling Fan (L)
X105-P4 to Cooling Fan (H)
Service Manual for Thermador Professional Series Built-in Wall Ovens
X105-6
BN
X205-4
LINE
Terminal
WH
Block
Figure 17 Halogen light transformer
4.12
Convection Fan Motor
The convection fan motor is 120V 29W. To test the motor, check for
120V across X105 / Pin 2 (upper/single) or X205 / Pin 1 (PODC) and
chassis ground or neutral.
The motor is accessible from the rear, after removing the rear outer
sheet metal panel.
1. Disconnect the 2 wires from the motor terminals.
2. Remove 3 T20 screws from the arms of the motor assembly.
3. Use a tap and a hammer to dislodge the assembly from the
clips that secure it to the rear of the unit. (Position tap on the
arm secured by the rightmost clip.)
Secondary
LINE
Terminals
Primary
LOAD
Terminals
OR
LOAD
OR