Error Codes; Error Code Table - Thermador Masterpiece ME271E Series Service Manual

Built-in wall ovens
Table of Contents

Advertisement

If the Hall effect sensor does not detect fan rotation, an error will
display. To test the upper fan at the control module, check voltage
across X105 / Pin 3 or 4 and neutral.
1. Remove 3 T20 screws securing the fan to the mounting
bracket.
2. Remove 3 T20 screws securing the bracket to the oven
housing.
3. Slide bracket up and out to release it from the 2 tabs holding it
in position.
4. Remove 3 T20 screws from the right side of the unit's top
panel.
5. Lift the right corner of the top panel and remove the fan/motor.
5

ERROR CODES

A Service Guide with error code information, wiring diagrams, and
instructions for entering Service Mode (if applicable) is packed with
every unit. Find it on the underside of the upper plenum access panel
as shown in Figure 18.
Figure 18 Location of Thermador Built-in Oven Service Guide
5.1

Error Code Table

The following table is included in the oven Service Guide. The error
codes which begin with E2 apply to the lower cavity of double ovens.
Diagrams referenced in the table can also be found in the appropriate
Service Guide.
Service Manual for Thermador Masterpiece Series Built-in Wall Ovens
CODE
DESCRIPTION
E000
Wrong module combination
E003
Electronics too hot
E005
Communication error
E009
ROM check error in user interface
E010
Data memory error in user interface
E011
Continuous pushing of single key
E012
Defective User Interface PCB temp.
sensor
E014
ON/OFF key does not work
E032
Continuous pushing of keys
E101/E201
Cvt 1/Cvt 2 Temp. sensor open
E104/E204
Cvt 1/Cvt 2/Temp. sensor shorted
E106/E206
Cvt 1/Cvt 2 Door latch does not lock
E107/E207
Cvt 1/Cvt 2 Door latch does not
unlock
E115/E215
Cvt 1/Cvt 2 Temp. in unlocked cavity
too high
E116
Cvt 1/Cvt 2 Probe error
CAUSE/ACTION
Control module and user
interface are mismatched. Set
Option Code properly.
User interface exceeds
185°F/85°C
Loss of communication
between user interface and
control module at start-up.
Check for ~4.9Vdc on middle
pin of communication
harness. Check connections
of all communication lines
and control module inputs.
User interface not getting all
information from control
module at start-up. Check for
loss of communication or
disconnected wire
somewhere in unit
Check user interface
assembly. Inspect touch
PCB.
10 seconds of multiple keys
being pressed.
Refer to Diagram 2/4
Refer to Diagram 2/4
Refer to Diagram 2/4
Refer to Diagram 2/4
Standard probe module is
part of the control module.
Refer to Diagram 1.