installation of the equipment.
• The equipment's power supply 2 complies with IEC/EN 61000-3-12.
• The equipment's power supply 2 shall be connected to a suitable supply network, with the following maximum permissible
system impedance Z
max
WH-MXF09D3E5 : 0.236Ω
Please liaise with supply authority to ensure that the power supply 2 is connected only to a supply of that impedance or less.
For WH-MXF12D6E5:
• The equipment's power supply 1 complies with IEC/EN 61000-3-12 provided that the short-circuit power S
equal to 817.851kW (for WH-MXF12D6E5) at the interface point between the user's supply and the public system. It is the
responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if
necessary, that the equipment is connected only to a supply with a short-circuit power S
• The equipment's power supply 1 shall be connected to a suitable supply network, having service current capacity ≥100A per
phase. Please liaise with supply authority to ensure that the service current capacity at the interface point is sufficient for the
installation of the equipment.
• The equipment's power supply 2 complies with IEC/EN 61000-3-12.
• The equipment's power supply 2 shall be connected to a suitable supply network, with the following maximum permissible
system impedance Z
max
WH-MXF12D6E5 : 0.236Ω
Please liaise with supply authority to ensure that the power supply 2 is connected only to a supply of that impedance or less.
• The equipment's power supply 3 complies with IEC/EN 61000-3-12.
• The equipment's power supply 3 shall be connected to a suitable supply network, with the following maximum permissible
system impedance Z
max
WH-MXF12D6E5 : 0.464Ω
Please liaise with supply authority to ensure that the power supply 3 is connected only to a supply of that impedance or less.
11.4.3. Wired Remote Controller Installation
Attached Accessories
No.
Name
(1)
Remote controller
(2)
Remote controller cable
(3)
Screw (M4 machine pitched - 30mm)
(4)
Screw (M4 self tapping - 14mm)
at the interface for models:
at the interface for models:
at the interface for models:
Qty.
1
1
3
3
Diagram
Length (15 m)
Installing the remote controller to an outlet box
(embedded cable)
Installing the remote controller to the wall
(exposed cable)
40
is greater than or
sc
greater than or equal to 817.851kW.
sc
Remark