Overall Checking; Standard Operation Conditions; Auto Random Re-Start Function - McQuay CK20AR Installation Manual

Cooling only heat pump ceiling cassette split type air conditioner
Table of Contents

Advertisement

• Ensure that :-
1) The unit has been mounted solidly and rigid in position.
2) Piping and connections are leak proof after charging.
3) Proper wiring has been installed.
• Drainage check - pour some water into the main drain pipe from the flexible drain hose.
• Test run
1) Conduct a test run after water drainage test and gas leakage test.
2) Check the following items :-
a. Is the electric plug firmly inserted into the socket ?
b. Is there any abnormal sound from the unit ?
c. Is there any abnormal vibration on the unit itself or piping ?
d. Is the drainage of water smooth ?
• Confirm that :
1) Condenser fan is running, with warm air blowing off the condensing unit.
2) Evaporator blower is running and discharge cool air.
3) The remote control incorporate a 3 minute delay in the circuit. Thus, it requires about 3 minutes before the outdoor
condensing unit can start up.
Cooling
Temperature
Minimum indoor
temperature
Maximum indoor
temperature
Minimum outdoor
temperature
Maximum outdoor
temperature
Disconnect from the main power supply before servicing the air conditioner unit.
DO NOT pull out the power cord when the power is ON. This may cause serious electrical shocks which
may result in fire hazards.
If there is a power cut when the unit is operating, it will automatically resume the same operating mode when the power is
restored. (Applicable only to units with this feature)
Before turning off the power supply, set the remote controller's ON/OFF switch to the "OFF" position to prevent the
nuisance tripping of the unit.
If this is not done, the unit's fans will start turning automatically when power resumes, posing a hazard to service
personnel or the user.
CK20A(1-16)ENG

OVERALL CHECKING

STANDARD OPERATION CONDITIONS

Ts
o
C
Th
o
C
16
11
32
23
16
11
43
26
! Warning

AUTO RANDOM RE-START FUNCTION

! Caution
15
Heating
Temperature
Minimum indoor
temperature
Maximum indoor
temperature
Minimum outdoor
temperature
Maximum outdoor
temperature
Ts : Dry bulb temperature.
Th : Wet bulb temperature.
1-15
2/1/01, 10:15 AM
o
o
Ts
C
Th
C
16
-
30
-
-5
-6
24
18