INDEX Maintenance page Models and dimensions page Replacing parts Gas ring ignition plung Data of appliances Gas ring tap Gas ring thermocouple Technical data Oven ignition plug Oven gas tap Operating instructions Oven thermocouple Construction, equipment installed Plug of ventilated gas oven and safety devices Ventilated gas oven gas valve Cooking top (gas)
2 - CHARACTERISTICS OF THE APPLIANCES These appliances are used for professional purposes. Installation, re- These instructions for installation are for our gas kitchens set up for pair and use must be carried out by expert personnel. the category in the table on page 5. The data plate is located on the front part of the appliance (on the control panel).
Page 5
TABLE 1 Model Solid Gas oven Gas oven Gas oven GN 1/1 Ø 70 Ø 90 Gas range GN 2/3 GN 1/1 ventilated Category II2H3+ Construction type Air necessary for combustion Nominal thermal power Minimum thermal power 0.75 Overall thermal power (gas) Hour consumption G30/G31 kg/h...
OPERATING INSTRUCTIONS Construction, equipment installed and type of gas available. safety devices If not, consult paragraph “Running the appliance on other types of gas”, page 8. Robust steel frame, with 4 legs (adjustable in height). 18/10 chrome-nickel steel outer panelling. Legal and technical requisites Cooking top (Gas) During assembly, the following legal and technical requisi-...
Wiring The connecting cable used for the appliance must be suited in section to the particular version and to its nomi- Before connecting the appliance to the electricity supply, nal capacity. Use an H07-RN-F type cable. check the following: - make sure the mains supply voltage matches the value Unipotential on the data plate;...
WARNING Replacing the oven nozzle (Fig. 3) It is not possible to adjust nominal capacity in advance. To gain access to the oven burner, remove the oven floor Checking power rating when using LP (from inside the oven cavity). Remove screws D (Fig. 3) and remove the burner by pul- ling it forwards;...
MAINTENANCE Oven gas tap (A - Fig. 3) Loosen the nuts on the thermocouple and on the gas pi- The following maintenance programme should be carried pes, draw the thermostat bulb out from the supporting cli- out at least once a year: ps inside the oven cavity and replace the tap with a - Check that all the safety and setting devices are new one.
USING THE APPLIANCE START-UP Lighting ventilated gas oven GN 1/1 (Fig. 3B) Turning a burner on and off cooking Turn on the switch located up the line from the unit. Press top (Fig. 2) the knob and turn it to the left until the spark position (5). Press the knob (H fig.
Page 13
TAKING CARE OF THE APPLIANCE FREQUENCY OF MAINTENANCE Giving the appliance a thorough clean every day (after tur- ning it off) will keep it in perfect working order and make it last longer. All steel parts should be cleaned with water and a deter- gent, using a damp cloth;...
Page 14
THE 2002/96/EC DIRECTIVE (WEEE): information to users This informational note is meant only for owners of equipment marked with the symbol shown in Fig. A on the adhesive label featuring the tech- nical specifications applied on the actual pro- duct (the label also giving the serial number). This symbol indicates that the product is classified, ac- cording to the regulations in force, as an item of electrical and electronic equipment and conforms to EU Directive...
WARNING DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPRO- VEMENT, THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY. THE MANUFACTURER CANNOT BE HELD RESPONSI- BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA- NUAL ARE NOT OBSERVED. THIS DOCUMENTATION IS ONLY INTENDED FOR QUALIFIED TECHNICIANS WHO ARE AWARE OF THE RESPECTIVE SAFETY REGULATIONS.
Need help?
Do you have a question about the ABA2001 and is the answer not in the manual?
Questions and answers