INDEX Adjusting the primary air Dimensions page page Maintenance Data of appliances Replacing parts Valve Technical data Safety termostat Burner Operating instructions Thermocouple Construction, equipment installed Ignition plug and safety devices Assembly Using the appliance Location Preparation for use Legal and technical requisites Filling the tank Installation Turning on and off...
2 - DATA OF APPLIANCES The instructions contained in this manual apply to our gas on the control panel. It contains all necessary reference bain-marie in the II2H3+ category (see table on page 5). data such as the name of the manufacturer, input pressu- The data plate is located on the front of the appliance and re, gas type setting, etc.
Page 5
TABLE 1 Model ABB00001 ADB00001 ACB00001 AEB00003 II2H3+ Category Construction type Air necessary for combustion Nominal thermal power Minimum thermal power Connection pressure Methane gas 2H 20 mbar Liquid gas 3+ G30/G31 28/37 mbar Gas connection values 0.254 0.423 Methane gas 2H (HuB = 9.45 kWh/m Liquid gas 3+ (HuB = 12.87 kWh/kg) kg/h...
OPERATING INSTRUCTIONS Construction, equipment installed Attention! and safety devices When installing the model ABB00001, make sure Robust steel frame, with 4 legs (adjustable in hei- that the front edge of the appliance is at a maxi- ght). mum distance of 100 mm from that of the suppor- 18/10 chrome-nickel steel outer panelling and tanks.
Installation procedure Gas venting To level the appliance correctly, adjust the height of These appliances are A construction type, thus no the four legs. gas venting is required. For advice on ventilating the premises where the Gas connection appliance is installed, observe current regulations. T h e R 1 / 2 ”...
WARNING - Remind the user that any structural alterations to the room housing the appliance may affect the It is not possible to adjust nominal capacity in ad- combustion air supply. Once the alterations have vance. been completed, the appliance and its functions Checking power rating when using should be thoroughly checked.
REPLACING PARTS Adjusting the primary air To adjust the primary air according to the data in ta- All parts must be replaced by authorised techni- ble (1), the fixing screw (99 - Fig. 1) must be loose- cians only! ned. To replace the following parts, remove the control panel (after unscrewing its fixing screws).
USING THE APPLIANCE Warning! L i g h t i n g t h e m a i n b u r n e r o f t h e tank - The appliance should never be left unattended when in use! To ligth the main burner, turn the knob to the posi- - Water should be added if the level drops below the mini-...
Floor-standing version TAKING CARE OF THE APPLIANCE FREQUENCY OF MAINTENANCE Check that the standard container is available for emptying procedure. The container should be pla- Warning! ced correctly on the proper guides and fully inser- ted. Never clean the appliance with jets of water, It is advisable to filter frying oil and fat daily and to whether direct or pressurised.
WARNING DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPRO- VEMENT, THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY. THE MANUFACTURER CANNOT BE HELD RESPONSI- BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA- NUAL ARE NOT OBSERVED. 054 - 03 - Gas Bain-marie...