mastro ABE0001 Installation, Operating And Maintenance Instructions

Gas pasta cooker

Advertisement

Quick Links

052_03
03/2006
Installation, operating and
maintenance instructions
GAS PASTA COOKER
ABE0001
ACE0005

Advertisement

Table of Contents
loading

Summary of Contents for mastro ABE0001

  • Page 1 052_03 03/2006 Installation, operating and maintenance instructions GAS PASTA COOKER ABE0001 ACE0005...
  • Page 2: Table Of Contents

    INDEX Models and dimensions Running the appliance on other types page of gas page Data of appliances Replacing the main burner nozzle Pilot injector replacement Technical data Adjusting the low flame Maintenance Operating instructions Replacing parts Construction, equipment installed Ignition plung and safety devices Gas tap Assembly...
  • Page 3: Models And Dimensions

    Models and dimensions ABE00001 600 x 650 x 300 weight approx.33,6 kg ACE00005 600 x 700 x 300 weight approx35,6 kg Drainage tap Inlet tap Gas control knob Piezo electric lighter Water inlet Gas connection 052 - 03 - Gas pasta cooker...
  • Page 4: Technical Data

    2 - DATA OF APPLIANCES The instructions contained in this manual apply to our gas on the control panel. It contains all necessary reference cookers in the II2H3+ category (see table on page 5). data such as the name of the manufacturer, input pressu- The data plate is located on the front of the appliance and re, gas type setting, etc.
  • Page 5 TABLE 1 ABE00001 Model ACE00005 II2H3+ Category Construction type Air necessary for combustion Nominal thermal power Minimum thermal power Connection pressure Methane gas 2H 20 mbar Liquid gas 3+ G30/G31 30/37 mbar Gas connection values 0.847 Methane gas 2H (HuB = 9.45 kWh/m Liquid gas 3+ (HuB = 12.87 kWh/kg) kg/h 0.631...
  • Page 6: Operating Instructions

    OPERATING INSTRUCTIONS Construction, equipment installed INSTALLATION and safety devices Assembly, installation and maintenance, i.e.: assembly, Robust steel frame, with 4 legs (adjustable in height). connecting the gas supply, checking power rating, 18/10 chrome-nickel steel outer panelling, tank in AISI transforming or adapting the appliance to run on other 316.
  • Page 7: Commissioning The Appliance

    COMMISSIONING THE APPLIANCE Before commissioning the appliance Checking power rating using the volumetric method Before commissioning the appliance, remove the pro- tective wrapping. Using a gas meter and a chronometer, you can read Thoroughly clean the work-surface and the outside of the volume of gas output per time unit.
  • Page 8: Checking The Pilot Light

    Checking the pilot light Main burner injector replacement (Fig. 1) When correctly adjusted, the pilot light flame will com- pletely surround the thermocouple and will not flicker. To replace the injector (30) dismount the front panel. Dismount the holding injector collector unscrewing the nut Checking the primary air 31 and the nut 32 on the gas cock.
  • Page 9: Replacing Parts

    REPLACING PARTS Loosen the gas piping and thermocouple hoses, then loosen the screws fixing the gas supply to the gas ramp and insert a new tap. All parts must be replaced by authorised techni- cians only! Thermocouple (Figs. 2 & 3) To replace the following parts, first remove the control Loosen the screws fixing the thermocouple (38) to the knobs, slide out the fat tray and remove the control pa-...
  • Page 10: Using The Appliance

    USING THE APPLIANCE START-UP TURNING THE APPLIANCE OFF FIRST-TIME USE OF THE APPLIANCE Turning the appliance off during Important! normal operation Before using the appliance for the first time, thorou- To turn the main burner off only, simply turn the knob ghly clean the tank with lukewarm water and deter- ;...
  • Page 11: Taking Care Of The Appliance Frequency Of Maintenance

    TAKING CARE OF THE APPLIANCE Precautions during use FREQUENCY OF MAINTENANCE Sauces and condiments: Giving the appliance a thorough clean every day (after tur- all the stainless steel containers used for notoriously acid ning it off) will keep it in perfect working order and make it ingredients (vinegar, salt, lemon juice, tomatoes, etc.) last longer.
  • Page 12: Warning

    WARNING DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPRO- VEMENT, THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY. THE MANUFACTURER CANNOT BE HELD RESPONSI- BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA- NUAL ARE NOT OBSERVED. 052 - 03 - Gas pasta cooker...

This manual is also suitable for:

Ace0005