ELECTRONIC CONTROLLER INSTRUCTION
Controlled
NO
FUCTION
Part
Initial
Buzzer ,Fan
1 1 1 1
Operation
Or Door lamp
Bar LED
88LED
Tempera-
Compressor
2 2 2 2
ture
F-fan
Control
C-fan
LED
Turbo
Compressor
3 3 3 3
Cooling
F-fan
C-fan
LED
1.Buzzer will ring 2 sec. after Plug-In.
2.88 LED displays micom version initially and does inside temperature in 2 sec.
3.Compressor runs ,if evaporator temperature is higher than 41.0°F(5.0°C).Compressor
will run 3 minutes after plug-in, if eva. temperature is lower than 41.1°F(5.0°C)
1.The temperature can be changed by pushing up/down buttons.
2.88LED displays inside temperature .
3.Buzzer buzzes 1 time whenever a button is pressed.
4.Compressor automatically turns on and off by D-sensor(Except error mode)
1.If Turbo Cooling button is pressed, Turbo Cooling mode will start.
2.If the Turbo Cooling button is pressed during Turbo Cooling mode, Turbo Cooling mode
can be canceled.
3.During Turbo Cooling mode, the temperature control button will not affect the
temperature control.
4.All bar LEDs are fully lighted during Turbo Cooling mode.
*NOTE*
D-sensor: Thermistor (Electrical resistance varies with temperature changing)
ACT Like thermostat. Detect eva. coil's temp. Wire color blue.
R-sensor: Thermistor
Act like thermometer. Detect inside air temp. Wire color is white.