Electric & Gas Connection; Electric Connection; Gas Regulator; If Using A Flexible Connection - La Germania LUG03-90-S Instruction Manual

Upright
Table of Contents

Advertisement

Electric & gas connection

Electric connection

The electric lead and plug are for connection onto a 10 Amp
socket. A 10 Amp socket is to be within 1m of the appliance.
The lead is situated at the left hand side of the cooker.

Gas regulator

The gas connection is via 1/2" compression. Connect the cooker
to the gas supply and check for gas soundness.

If using a flexible connection

This appliance is approved for connection by a CLASS B hose.
Connection is in compliance with AS 5601, clause 5.12.1.8.

If using copper connection

To allow cooker to be moved forward for service make a loop in
the copper tube before connecting onto regulator.

Gas connection

The cooker must be connected to the gas supply with upstream
connection of an isolation valve in accordance with the respective
valid regulations. We recommend that the isolation valve be
fitted prior to the cooker to enable isolation of the cooker from
the gas supply. The valve must be easily accessible at all times.
To find out the factory set gas type, see label at rear of cooker.
The connection is via 1/2" compression. Connect the cooker to
the gas supply and check for gas soundness. NEVER use a naked
flame to check for leaks.
Gas inlet (mm) position
- Nat Gas
From RH rear side: 35mm ¢
Up from floor: 590mm
Gas inlet position with different leg heights - mm
Min
Ref
Max
8
Gas inlet (mm) position
- LPG.
From RH rear side: 35mm ¢
Up from floor: 675mm
NG: 560
LP:
645
NG: 590
LP:
675
NG: 595
LP:
680
combination. Burner flames should be clear blue, with no yellow
tipping. If the burners show any abnormality check that burner
heads are correctly located. If satisfactory performance can not
be obtained, contact SampfordIXL or the local gas utility. For
service contact number refer page 9.
To clean or replace a cooktop burner injector
1. Remove pan support, burner cap and burner head.
2. Using a 7mm socket spanner unscrew and clean or replace
the boiling burner's injector.
3. Replace burner heads, caps and pan support. Ensure that
the burner head and cap are in the correct position.
To replace a cooktop burner electronic spark electrode
1. Follow procedure as per the heading 'Access to under hob
area.
2. Remove the spring clip securing the spark electrode to the
burner head.
3. Unplug the electronic connector from the electronic control
module.
4. Replace the spark electrode ensuring that the electrode is in
the correct position.
5. Reassemble the cooker in the reverse order.
To replace the minute minder
Pull cooker forward and follow procedure as per heading ' Access
to under hob area'.
1. From the front undo the 2 phillips head screws securing the
minute minder to the fascia support plate.
2. Replace the minute minder and reassemble in reverse order.
To replace thermostat
Follow access procedure as per the heading 'To replace gas
control valves'.
Please note that the thermostat has a fixed control - no adjustment
is necessary.
1. Remove the rear panel of the cooker by unscrewing 7 phillips
head retaining screws.
2. Unclip the thermostat bulb from the rear wall of the oven and
pull the bulb up through the rear cavity of the cooker.
3. Unclip the electronic connectors from the thermostat. Mark
the connectors so they are replaced in the correct position.
4. Using a phillips head screwdriver unscrew the 2 clamping
screws at the bottom of the gas manifold.
5. Replace thermostat and secure to the manifold with the 2
clamping screws.
25

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for La Germania LUG03-90-S

Table of Contents