OPERATING PROCEDURE

1. POWER-UP

Connect Pro-X power cord to power source making sure that the voltage is correct for the model of
welder you have. Please refer to page 4 and 5 of this manual for details.
Both temperature controllers should illuminate and display current temperature of barrel and pre-heat air
(usually ambient temperature when starting-up for the first time that day).
Switch the pre-heat blower fan rocker switch located on the control panel to the "on" position (up). The
hot air blower unit, situated on top of the welder should turn on and air should begin blowing out of pre-
heat nozzle at the end of the barrel.
Switch the pre-heater element rocker switch located on the rear of the green colored pre-heat blower unit
to the on or "I" position. This will allow the pre-heat air to begin heating.

SETTING/ADJUSTING OPERATING TEMPERATURES:

Note:
There are two temperature controllers located on the main control panel. The one on
the top controls the hot air pre-heat temperature and the one on the bottom controls
the barrel (molten rod) temperature.
For recommended temperature settings, please refer to chart below or contact
Demtech technical support for advice.

RECOMMENDED TEMPERATURE SETTINGS:

Temperature setting will vary a great deal due to the wide range of variables that can be experienced in
the field. For example, ambient temperature, sheet temperature, sheet thickness, wind conditions, etc.
will vary. As it is difficult to create a chart that covers all conditions, we recommend contacting Demtech
with information on the above conditions. We will be happy to recommend appropriate settings.
6