HYT TC-508 Service Manual page 57

Hide thumbs Also See for TC-508:
Table of Contents

Advertisement

Service Manual
MCU Section
9.3
Start
Normal power-up
alert tone?
Yes
No
Normal speaker?
Yes
Normal MCU
VCC?
Yes
Normal MCU
X601?
Yes
Other control pins
are normal?
Yes
MCU is OK
No
Replace it
Check U601,
No
U602, U604,
and U606
No
Replace X601
Check pin
No
connection or
reburn the
program
55
Troubleshooting Flow Chart

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents