Ruin & Wesen Midi Command User Manual page 28

Table of Contents

Advertisement

Ruin & Wesen Electronics
Midi Command Page Format
This section documents the format of page data in memory. This format is also used when sending page data over
sysex.
Midi Page format
Byte
CCs (4 bytes)
Channel (4 bytes)
Macro (8 times 2 bytes) = lower
boundary (1 byte), upper boundary (1
byte)
Names (4 times 4 characters)
MachineDrum Page format
This format is used for all the 4 types of MachineDrum pages.
Byte
Parameter number (4 bytes)
Unused (4 bytes)
Macro (8 times 2 bytes) = lower
boundary (1 byte), upper boundary (1
byte)
Midi Command Documentation
Purpose
CC number for each encoder
Channel number for each encoder
Lower and upper boundaries for the
macro knob
Name of each encoder (4 chars)
Purpose
The parameter number of the
parameter on the effect page
Unused bytes
Lower and upper boundaries for the
macro knob