B. Fold Quality Needs Improving
1. Make sure paper is squared and installed correctly. Side guides should be evenly balanced
and snug against the paper.
2. If folds are still incorrect adjust fold plates (see fold plate adjustment on page 3).
C. Paper is not Folding Square (Skewing)
1. If paper pulls left or right adjust the skew adjuster. To adjust the skew, turn the skew
adjuster (figure 6) left or right until the paper is feeding correctly.
(figure 6)
D. Ready light is not illuminated and power is on:
1. Press the black button (figure 3) near the power cord inlet to reset the breaker.
E. Ready light is blinking red:
1. Check to see that the top cover is installed properly.
2. Check to insure that the photo-eye, before the metal sealer rollers, is clear of forms and/or
paper dust.
:
: