Spyder 3 CL User's Manual
3.3 Camera Output Format
How to Configure Camera Output
Using the camera link mode and pixel readout direction commands
Use the camera link mode (
configuration, the number of output taps, and the bit depth. Use the pixel readout
direction (
The following tables summarize the possible camera configurations for each of the S3-xx
camera models.
Table 9: S3-X0-01K40 Data Readout Configurations
Camera Link Mode Configuration (Controlled by clm
command)
Command
clm 0
clm 1
clm 2
clm 3
DALSA
clm)
command to select the camera's pixel readout direction.
smm)
Models
CCD and Camera
Link Taps
S3-10-01K40
1 Camera Link taps
S3-10-02K40
S3-10-01K40
1 Camera Link taps
S3-10-02K40
S3-20-01K40
2 Camera Link taps
S3-20-02K40
S3-20-01K40
2 Camera Link taps
S3-20-02K40
command to determine the camera's Camera Link
Readout Direction
(Controlled by
command)
Bit
smm 0 increment =1
Depth
smm 1 increment = -1
8
smm 0
smm 1
smm 0
smm 1
12
smm 0
smm 1
smm 0
smm 1
8
smm 0
smm 1
smm 0
smm 1
12
smm 0
smm 1
smm 0
smm 1
smm
= CL tap 1 (1-1024)
= CL tap 1 (1024-1)
= CL tap 1 (1-2048)
= CL tap 1 (2048-1)
= CL tap 1 (1-1024)
= CL tap 1 (1024-1)
= CL tap 1 (1-2048)
= CL tap 1 (2048-1)
= CL tap 1 (1-512)
CL tap 2 (513-1024)
= CL tap 1 (1024-513)
CL tap 2 (512-1)
= CL tap 1 (1-1024)
CL tap 2 (1025-2048)
= CL tap 1 (2048-1025)
CL tap 2 (1024-1)
= CL tap 1 (1-512)
CL tap 2 (513-1024)
= CL tap 1 (1024-513)
CL tap 2 (512-1)
= CL tap 1 (1-1024)
CL tap 2 (1025-2048)
= CL tap 1 (2048-1025)
CL tap 2 (1024-1)
03-032-20008-00
29
Need help?