OPERATIONAL NOTE: TO CONSERVE BATTERY POWER, CHANGES IN TEMPERATURE ARE ONLY RECORDED EVERY TWO
MINUTES. Additionally, to prevent repeated thermo-cycling of the gas appliance, the sensing unit in the transmitter will only activate
the remote receiver when the temperature change exceeds 2
the "SWING" setting has been changed from the factory setting (2
"SWING" number.
MANUAL CHECK OF THERMO OPERATION
The operation of the Thermo setting can be checked on demand by adjusting the SET temperature 2
temperature, which will cause the system to turn ON or OFF, respectively. Normally, however, the system will only respond to
temperature changes every two minutes. NOTE: if "SWING" number has been changed, then activation will occur at the new "SWING"
setting.
When the gas fireplace system is activated, a FLAME icon will display on the LCD screen indicating a signal has been sent from the
transmitter.

OPERATING INSTRUCTIONS

THERMO OPERATION – (Systems operates thermostatically based on SET TEMP setting, ONLY)
1
2
1
2
1,2
3
TU
ON
THERMO
PM
TIME
FLAME
MO
DAY
PROGRAM
ON
OVERRIDE
TEMP
SET
FLAME
MO
DAY
PROGRAM
ON
HOLD
TEMP
SET
FLAME
0
0
F (1
C) above or below the SET (desired) temperature. However, if
0
0
F /1
C), then thermo-cycling will activate at the new setting of the
SETTING DESIRED ROOM TEMPERATURE
This remote control system can be thermostatically controlled
when the transmitter is in the THERMO mode (THERMO must
be displayed on the screen).
1.
To set the DESIRED
MODE button to place the transmitter into THERMO
mode. THERMO ON or OFF will display.
2.
Then press the UP or DOWN button to select the
DESIRED room temperature. The highest SET
temperature is 99
temperature is 45
3.
The TRANSMITTER will "sense" the room temperature
every two minutes automatically turning the fireplace ON
or OFF thermostatically.
TEMPERATURE OVERRIDE – (Operates only in PROGRAM
mode)
The user may change the current SET temperature without
changing the programs stored in the transmitter's memory.
The OVERRIDE feature will be automatically cancelled at the
start of the next PROGRAM PERIOD.
1.
To change current SET TEMP, press the UP or DOWN
button (Setting will be cancelled automatically when next
program period begins.) The word OVERRIDE will appear
over the SET frame on the LCD.
2.
To cancel temperature OVERRIDE, press SET button.
TEMPERATURE HOLD – (Operates only in PROGRAM
mode.)
The user may override the SET temperature during any period,
adjusting the SET temperature to a CONSTANT new
SET/HOLD temperature.
1.
Press the UP or DOWN button to change the SET
temperature to the level desired. The word OVERRIDE
will appear in SET frame on the LCD.
0
F above or below the room
room temperature, press the
0
0
F (32
C). The lowest SET
0
0
F (6
C).
REV 8/21/06 Page 6 of 16