Summary of Contents for Lamborghini Caloreclima TAURA D 24 MCA
Page 1
D 24 MCA D 32 MCA Ø143 Ø131 Ø24,5 Ø30 Ø24,5 Ø30 Ø24,5 Ø30 Ø24,5 Ø24,5 Ø30 Ø24,5 60 60 86 60 61 59 80,5 A B C B C D 36,5 80,5 198.5 201.5 TAURA D MCA IT - ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE ES - INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO EN - INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE FR - INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN...
TAURA D MCA Anomalia In caso di anomalia (vedi cap. 4.4) il display visualizza il codice di guasto (part. 11 - fig. 1) e durante i tempi di attesa di sicurezza le scritte “d3” e “d4”. 2.3 Accensione e spegnimento 1.
TAURA D MCA Temperatura scorrevole 3. INSTALLAZIONE Quando viene installata la sonda esterna (opzionale) il sistema di regolazione caldaia la- 3.1 Disposizioni generali vora con “Temperatura Scorrevole”. In questa modalità, la temperatura dell’impianto di L'INSTALLAZIONE DELLA CALDAIA DEVE ESSERE EFFETTUATA SOLTANTO DA riscaldamento viene regolata a seconda delle condizioni climatiche esterne, in modo da PERSONALE SPECIALIZZATO E DI SICURA QUALIFICAZIONE, OTTEMPERANDO A garantire un elevato comfort e risparmio energetico durante tutto il periodo dell’anno.
TAURA D MCA Termostato ambiente (opzional) 4. SERVIZIO E MANUTENZIONE ATTENZIONE: IL TERMOSTATO AMBIENTE DEVE ESSERE A CONTATTI 4.1 Regolazioni PULITI. COLLEGANDO 230 V. AI MORSETTI DEL TERMOSTATO AMBIEN- Trasformazione gas di alimentazione TE SI DANNEGGIA IRRIMEDIABILMENTE LA SCHEDA ELETTRONICA. L’apparecchio può...
Page 5
TAURA D MCA Indice Descrizione Range Default TAURA D MCA A - Presa di pressione a monte Selezione funzio- 0 = Valvola gas esterna B - Presa di pressione a valle namento 0=Valvola gas 0=Valvola gas 1 = Elettrovalvola caricamento impianto I - Connessione elettrica Valvola gas scheda relè...
Page 6
TAURA D MCA Menù service “In” - Menù Informazioni L’acceso al Menù Service della scheda avviene premendo il tasto Reset per 20 secondi. Sono disponibili 7 informazioni. Sono disponibili 4 sotto menù: premendo i tasti Riscaldamento sarà possibile scegliere, Premendo i tasti Riscaldamento sarà possibile scorrere la lista delle informazioni, rispet- rispettivamente in ordine crescente o decrescente, “tS”, “In”, “Hi”...
TAURA D MCA 4.3 Manutenzione Codice Anomalia Possibile causa Soluzione anomalia Controllo periodico Cablaggio interrotto Verificare il cablaggio Per mantenere nel tempo il corretto funzionamento dell’apparecchio, è necessario far Anomalia valvola gas eseguire da personale qualificato un controllo annuale che preveda le seguenti verifiche: Verificare ed eventualmente sostitu- Valvola gas difettosa ire la valvola gas...
Page 8
5.1 Vista generale e componenti principali 5.2 Schemi idraulici fig. 15 - Circuito Riscaldamento fig. 13 - Vista generale TAURA D 24 MCA fig. 16 - Circuito Sanitario fig. 14 - Vista generale TAURA D 32 MCA cod. 3541A212 - 04/2012 (Rev. 00)
Page 9
Capacità vaso di espansione riscaldamento litri Q [l/h] Pressione precarica vaso di espansione riscaldamento fig. 19 - Perdite di carico / prevalenza circolatori (TAURA D 24 MCA) Pressione max di esercizio sanitario (PMW) H [m H Pressione min di esercizio sanitario 0.25...
TAURA D MCA 2.3 Encendido y apagado Conexión a la red eléctrica • Durante los 5 primeros segundos, en la pantalla se visualiza la versión del software de la tarjeta. 1. ADVERTENCIAS GENERALES • Abrir la llave del gas ubicada antes de la caldera. •...
TAURA D MCA Temperatura adaptable 3. MONTAJE Si está instalada la sonda exterior (opcional), el sistema de regulación de la caldera fun- 3.1 Disposiciones generales ciona con “Temperatura adaptable”. En esta modalidad, la temperatura del circuito de LA CALDERA TIENE QUE SER INSTALADA ÚNICAMENTE POR PERSONAL ESPE- calefacción se regula en función de las condiciones climáticas exteriores, con el fin de CIALIZADO Y DEBIDAMENTE CUALIFICADO, RESPETANDO TODAS LAS INS- garantizar mayor confort y ahorro de energía durante todo el año.
TAURA D MCA Termostato de ambiente (opcional) 4. SERVICIO Y MANTENIMIENTO ATENCIÓN: EL TERMOSTATO DE AMBIENTE DEBE TENER LOS CONTAC- 4.1 Regulaciones TOS LIBRES DE POTENCIAL. SI SE CONECTAN 230 V A LOS BORNES Cambio de gas DEL TERMOSTATO DE AMBIENTE, LA TARJETA ELECTRÓNICA SE DAÑA El equipo puede funcionar con gas metano o GLP.
TAURA D MCA Índice Descripción Rango Predeterminado TAURA D MCA A - Toma de presión aguas arriba Selección del 0 = válvula del gas externa B - Toma de presión aguas abajo modo de funciona- 1 = electroválvula de carga de la instalación I - Conexión eléctrica de la válvula del gas 0 = válvula del gas 0 = válvula del...
Page 15
TAURA D MCA Menú Service "In" - Menú Información Para entrar en el Menú Service de la tarjeta, presionar la tecla Reset durante 20 segun- Hay siete informaciones. dos. Hay cuatro submenús disponibles: pulsar las teclas de la calefacción para seleccio- Pulsando las teclas de la calefacción se puede recorrer la lista de informaciones en or- nar (en orden creciente o decreciente) "tS", "In", "Hi"...
TAURA D MCA 4.3 Mantenimiento Código Anomalía Causa posible Solución anomalía Control periódico Anomalía de los paráme- Parámetro de la tarjeta mal confi- Controlar el parámetro de la tarjeta y Para que el aparato funcione correctamente, es necesario que un técnico cualificado ve- tros de la tarjeta gurado modificarlo si corresponde.
Page 17
5.1 Vista general y componentes principales 5.2 Esquemas hidráulicos fig. 15 - Circuito de calefacción fig. 13 - Vista general TAURA D 24 MCA fig. 16 - Circuito de AS fig. 14 - Vista general TAURA D 32 MCA cod. 3541A212 - 04/2012 (Rev. 00)
Page 18
20 - Pérdidas de carga / altura manométrica bombas de circulación (TAURA D 32 MCA) A = Pérdida de carga de la caldera - 1, 2 y 3 = velocidades bomba fig. 17 - Diagrama presión - potencia (TAURA D 24 MCA) cod. 3541A212 - 04/2012 (Rev. 00)
TAURA D MCA 2.3 Lighting and turning off Connection to the power supply • During the first 5 seconds the display will also show the card software release. • Open the gas cock ahead of the boiler. 1. GENERAL INSTRUCTIONS •...
TAURA D MCA Sliding Temperature 3. INSTALLATION When the optional external probe is installed, the boiler adjustment system works with 3.1 General Instructions "Sliding Temperature”. In this mode, the temperature of the heating system is controlled BOILER INSTALLATION MUST ONLY BE PERFORMED BY QUALIFIED PERSON- according to the outside weather conditions, to ensure high comfort and energy saving NEL, IN ACCORDANCE WITH ALL THE INSTRUCTIONS GIVEN IN THIS TECHNICAL throughout the year.
TAURA D MCA Room thermostat (optional) The boiler is also equipped with a safety device (fume thermostat) that stops operation of unit in case of inadequate draught of obstruction of the flue. This IMPORTANT: THE ROOM THERMOSTAT MUST HAVE VOLTAGE-FREE device must never be tampered with or deactivated.
TAURA D MCA Contents Description Range Default TAURA D MCA A - Upstream pressure point 0 = External gas valve Relay card LC32 B - Downstream pressure point 0=External gas 0=External gas operation selec- 1 = System filling solenoid valve I - Gas valve electrical connection valve valve...
Page 24
TAURA D MCA Service menu "In” - Information Menu The card Service Menu is accessed by pressing the Reset button for 20 seconds. 4 sub- 7 pieces of information are available. menus are available: press the Heating buttons to select, in increasing or decreasing or- Press the Heating buttons to scroll the list of information in increasing or decreasing or- der, "tS", "In", "Hi"...
TAURA D MCA 4.3 Maintenance Fault Fault Possible cause Cure code Periodical check Sensor damaged To ensure correct operation of the unit over time, have qualified personnel carry out a Check the wiring or replace the sen- yearly check, providing for the following: DHW sensor fault Wiring shorted •...
Page 26
5.1 General view and main components 5.2 Plumbing diagrams fig. 15 - Heating Circuit fig. 13 - General view TAURA D 24 MCA fig. 16 - DHW Circuit fig. 14 - General view TAURA D 32 MCA cod. 3541A212 - 04/2012 (Rev. 00)
Heating expansion tank capacity litres Q [l/h] Heating expansion tank prefilling pressure fig. 19 - Circulating pump head / pressure losses (TAURA D 24 MCA) Max. working pressure in hot water production (PMW) H [m H Min. working pressure in hot water production 0.25...
TAURA D MCA Anomalie En cas de panne (voir cap. 4.4), l'afficheur visualise le code d'erreur (rep. 11 - fig. 1) et les messages "d3" et "d4" durant le temps d'attente de sécurité. 2.3 Allumage et extinction 1. AVERTISSEMENTS GÉNÉRAUX Raccordement au réseau électrique •...
Page 30
TAURA D MCA Température évolutive 3. INSTALLATION Si la sonde extérieure (option) est montée, le système de réglage de la chaudière tra- 3.1 Dispositions générales vaillera en “Température évolutive”. Dans ce mode, la température de l'installation L'INSTALLATION DE LA CHAUDIÈRE DOIT ÊTRE EFFECTUÉE CONFORMÉMENT chauffage est régulée en fonction des conditions climatiques extérieures de manière à...
TAURA D MCA Thermostat d'ambiance (optionnel) 4. UTILISATION ET ENTRETIEN ATTENTION : LE THERMOSTAT D'AMBIANCE DOIT ÊTRE À CONTACTS 4.1 Réglages PROPRES. EN RELIANT 230 V. AUX BORNES DU THERMOSTAT, LA CAR- Transformation du gaz d'alimentation TE ÉLECTRONIQUE EST IRRÉMÉDIABLEMENT DÉTÉRIORÉE. L'appareil peut fonctionner au gaz naturel ou gaz liquide, et est prédisposé...
Page 32
TAURA D MCA Som- Description Plage Défaut TAURA D MCA A - Prise de pression en amont maire B - Prise de pression en aval Sélection fonction- 0 = Vanne gaz extérieure I - Connexion électrique soupape de gaz nement 0 = Vanne gaz 0 = Vanne gaz 1 = Électrovanne de remplissage installation...
Page 33
TAURA D MCA Menu Service « In » - Menu Informations Appuyer 20 secondes sur la touche Reset pour accéder au Menu Service de la carte. 4 7 informations sont disponibles. sous-menus sont disponibles : appuyer sur les touches Chauffage pour choisir, respec- En appuyant sur les touches Chauffage, il sera possible de parcourir la liste des infor- tivement dans l'ordre croissant ou décroissant, «...
TAURA D MCA 4.3 Entretien Code Anomalie Causes probables Solution anomalie Contrôle périodique Basse pression dans l'installation Pour un fonctionnement correct durable de l'appareil, il est nécessaire de faire effectuer Vérifier la pression du gaz d'alimentation du gaz Absence de flamme après par un professionnel qualifié...
TAURA D MCA 2.3 Pornirea i oprirea Racordarea la re eaua electric • În timpul primelor 5 secunde, pe afi aj apare versiunea software a cartelei. • Deschide i robinetul de gaz din amonte de central . 1. AVERTISMENTE GENERALE •...
TAURA D MCA Temperatur variabil 3. INSTALAREA Când e instalat sonda extern (op ional), sistemul de reglare al centralei lucreaz cu 3.1 Dispozi ii generale “Temperatur variabil ”. În acest mod, temperatura din instala ia de înc lzire este regla- INSTALAREA CENTRALEI TREBUIE EFECTUAT NUMAI DE PERSONAL SPECIA- t în func ie de condi iile climatice externe, astfel încât s se garanteze un confort ridicat LIZAT...
TAURA D MCA Termostatul de camer (op ional) 4. EXPLOATAREA I ÎNTRE INEREA ATEN IE: TERMOSTATUL DE CAMER TREBUIE S AIB CONTACTELE 4.1 Regl rile CURATE. DAC SE CONECTEAZ 230 V. LA BORNELE TERMOSTATULUI Transformarea gazului de alimentare DE CAMER , SE DETERIOREAZ IREMEDIABIL CARTELA ELECTRONI- Aparatul poate func iona cu alimentare cu gaz metan sau G.P.L.
Page 50
TAURA D MCA Cuprins Descriere Interval Implicit TAURA D MCA A - Priza de presiune din amonte Selectarea 0 = Valv de gaz extern B - Priza de presiune din aval func ion rii 0 = Valv de gaz 0 = Valv de gaz 1 = Electrovalv umplere instala ie I - Conexiune electric valv gaz cartel releu LC32...
Page 51
TAURA D MCA Meniul service “In” - Meniul Informa ii Pentru a ajunge la Meniul Service al cartelei, ap sa i tasta Reset timp de 20 secunde Sunt disponibile 7 informa ii. Sunt disponibile 4 submeniuri: ap sând pe tastele pentru Înc lzire se poate alege, în or- Ap sând pe tastele pentru Înc lzire se poate derula lista informa iilor, în ordine cresc to- dine cresc toare, respectiv descresc toare, “tS”, “In”, “Hi”...
TAURA D MCA 4.3 Între inerea Anomalie Cauz posibil Solu ie anomalie Controlul periodic Cablaj întrerupt Verifica i cablajul Pentru a men ine în timp corecta func ionare a aparatului, e necesar s solicita i perso- Anomalie valv gaz nalului calificat un control anual care s prevad urm toarele verific ri: Verifica i i eventual înlocui i valva de Valv de gaz defect •...
Page 53
5.2 Scheme hidraulice fig. 15 - Circuitul de înc lzire fig. 13 - Vedere general TAURA D 24 MCA fig. 16 - Circuitul de ap cald menajer fig. 14 - Vedere general TAURA D 32 MCA cod. 3541A212 - 04/2012 (Rev. 00)
20 - Pierderi de sarcin / în l ime de pompare pompe de circula ie (TAURA D 32 MCA) A = Pierderi de sarcin în central - 1, 2 i 3 = Vitez pomp de circula ie fig. 17 - Diagram presiune - putere (TAURA D 24 MCA) cod. 3541A212 - 04/2012 (Rev. 00)
Page 55
TAURA D MCA 5.5 Schem electric ABM01 ° ° ° 230V 50 Hz fig. 21 - Circuitul electric cod. 3541A212 - 04/2012 (Rev. 00)
Dichiarazione di conformità Il costruttore dichiara che questo apparecchio è conforme alle seguenti direttive CEE: • Direttiva Apparecchi a Gas 2009/142 • Direttiva Rendimenti 92/42 • Direttiva Bassa Tensione 2006/95 • Direttiva Compatibilità Elettromagnetica 2004/108 Declaración de conformidad El fabricante declara que este equipo satisface las siguientes directivas CEE: •...
Declara ie de conformitate Produc tor declar c acest aparat este în conformitate cu urm toarele directive CEE: • Directiva Aparate cu Gaz 2009/142 • Directiva Randament 92/42 • Directiva Joas Tensiune 2006/95 • Directiva Compatibilitate Electromagnetic 2004/108 CEE: • 2009/142 •...
Page 68
BRUCIATORI CALDAIE MURALI E TERRA A GAS GRUPPI TERMICI IN GHISA E IN ACCIAIO GENERATORI DI ARIA CALDA TRATTAMENTO ACQUA CONDIZIONAMENTO Le illustrazioni e i dati riportati sono indicativi e non impegnano. La LAMBORGHINI si riserva il diritto di apportare senza obbligo di preavviso tutte le modifiche che ritiene più...