Olimpia splendid Unico Instructions For Installation, Use And Maintenance Manual

Olimpia splendid Unico Instructions For Installation, Use And Maintenance Manual

Advertisement

INVERTER
I
ISTRUZIONI PER INSTALLAZIONE, USO E MANUTENZIONE
GB
INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE
F
INSTRUCTIONS POUR L'INSTALLATION, L'EMPLOI ET L'ENTRETIEN
D
HANDBUCH FÜR INSTALLATION, GEBRAUCH UND WARTUNG
E
INSTRUCCIONES PARA LA INSTALACIÓN, USO Y MANTENIMIENTO

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Unico and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Olimpia splendid Unico

  • Page 1 INVERTER ISTRUZIONI PER INSTALLAZIONE, USO E MANUTENZIONE INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE INSTRUCTIONS POUR L'INSTALLATION, L'EMPLOI ET L'ENTRETIEN HANDBUCH FÜR INSTALLATION, GEBRAUCH UND WARTUNG INSTRUCCIONES PARA LA INSTALACIÓN, USO Y MANTENIMIENTO...
  • Page 2 9 11 6 0 m 6 0 m m...
  • Page 3 UNICO - INVERTER...
  • Page 5 UNICO - INVERTER...
  • Page 6 LED D LED C LED B LED A...
  • Page 7 UNICO - INVERTER...
  • Page 8 AUTO AUTO...
  • Page 9: Table Of Contents

    3.3.18 Managing the unit if the remote control is not available -------------------------------------------------------------- 38 ENERGY SAVING ADVICE ------------------------------------------------------------------------------------------------- 38 TROUBLESHOOTING -------------------------------------------------------------------------------------------------------- 38 3.5.1 Functional aspects not to be interpreted as problems ---------------------------------------------------------------- 38 3.5.2 Troubleshooting ---------------------------------------------------------------------------------------------------------------- 39 3.5.3 Specifications ------------------------------------------------------------------------------------------------------------------ 40 UNICO INVERTER...
  • Page 10: Symbols

    GENERAL SYMBOLS The pictograms shown in the next chapter provide the information necessary for correct use of the appliance in a rapid and unmistakable way. 1.1.1 Editorial pictograms Service Refers to situations in which you should inform the SERVICE department in the company: CUSTOMER TECHNICAL SERVICE.
  • Page 11: Warning

    The air-conditioner should be used for the exclusive purpose of producing hot or cool air (on demand) for the sole purpose of obtaining a comfortable temperature in the room. Improper use of the equipment, which may cause injury/damage to persons, property or animals, relieves OLIMPIA SPLENDID of any liability.
  • Page 12: Storage

    3 days of receipt of the goods and enclosing photographic evidence. Send the same information by fax to OLIMPIA SPLENDID. No complaints will be accepted if made more than 3 days after the delivery of the goods.
  • Page 13: Installation Modes

    The UNICO INVERTER unit may be installed in lieu of a UNICO SKY or UNICO STAR unit without changing the position of the existing holes, with the exception of the small hole for condensate drainage. In this case, in order not to penalize performance, remove the insulating material from the air outlet pipe.
  • Page 14: Preparing The Condensate Discharge

    To prevent the creation of large amounts of dust and rubble due to drilling, the core borer can be fitted with a vacuum system applied by means of suction cups to the drilling zone. Our Service Department can give you all necessary information to enable you to find these devices.
  • Page 15: Preparing The Holes On The Machine

    If it is installed near an outlet, you need only plug it in. WARNING: the replacement of the power supply cable, if needed, must be made by OLIMPIA SPLENDID technical service only, or by personnel with similar qualifications and expertise.
  • Page 16: Top/Bottom Installation Configuration

    close the protection of the board (fig. 19 ref. A) refit the front cover of the machine with the six screws refit the two wedged-in covers (upper and lower). CAUTION: these operations should be performed with the machine already positioned on the bracket. Read the instructions carefully before completely the electric connection.
  • Page 17: Evacuating Condensate Water During An Emergency

    WARNING: after having cleaned the filters, the air suction flap might stop in a wrong position on turning on the unit again. In this case: turn off the unit manually move the suction flap to closed position cut off power supply (disconnect the power cable) wait about 30 seconds plug in the power cable turn on the unit. UNICO INVERTER...
  • Page 18: Warnings

    USE AND MAINTENANCE (user part) WARNINGS The installation and electrical connection of the air conditioner should be carried out by specialized personnel who possess the requisites set forth by law. The installation instructions are provided in the specific manual. No structural object (furniture, curtains, plants, leaves, blinds, etc.) should ever obstruct the normal flow of air from either the internal or external gratings.
  • Page 19: Remote Control

    In case of prolonged stop of the machine, it must be deactivated turning the main switch off or unplugging the machine from the mains. 3.3.4 ECO key (button T2) The energy saving function is activated through this button (T2) and the switching on of the ECO icon remote control on the display, which automatically optimizes machine running. UNICO INVERTER...
  • Page 20: Cooling

    3.3.5 Cooling When used in this mode, the air conditioner dehumidifies and cools the room. Activate this mode by pressing button (T4) Run mode selector until the snowflake symbol (D3) is displayed. In this run mode, the required temperature and fan speed can be set. After having activated this run mode, the compressor will start running after 3 minutes at the most and the unit begins emitting cold air.
  • Page 21: Checking Fan Speed

    30 minutes. To return to the routine operating mode just press the button (T6) as many times as necessary to clear the relevant indications from the display. UNICO INVERTER...
  • Page 22: Starting And Stopping The Operating Programs

    3.3.16 Starting and stopping the operating programs After having made the settings for the operating programs, they can be used or not, as needed. Either or both of the programs can be used. In particular, each time you press the button (T11) Program activation, the situation changes as follows: Use of Program no.
  • Page 23: Troubleshooting

    • Remove anything that might clog the air flows. • The heating/cooling load has increased (for example a door or a window was left open or equipment that dissipates a large amount of heat was installed in the same room). UNICO INVERTER...
  • Page 24: Specifications

    3.5.3 Specifications For the technical data listed below, consult the characteristic data plate applied to the product - Power supply voltage - Maximum power absorbed - Maximum current absorbed - Coolant power - Coolant gas - Protection rating of the containers - Max working pressure Dimensions (W x H x D) mm 902x506x229...