The selector uses a four-station switch system that allows selection of the standard
features and customized installation settings. The switch description is as follows:
Note: The power should always be turned off when designating feature selector switches
FEATURE SELECTOR
The reset button is used to reset the micropressor.
IF YOU MAKE A CHANGE WITH THE SWITCHES, YOU
MUST USE THE RESET BUTTON TO APPLY CHANGES.
Note: If the power light is on and the operator does
not function, press the reset button once. If this does
not solve the problem, proceed with turning off the
power switch and then switching it back on again.
Eagle Access Control Systems, Inc. / (800) 708-8848 / www.eagleoperators.com
EAGLE-II Swing Gate Operator
____________________

The Feature Selector

Switch 1: Slave/Master - Sets the operator
to work as Master or Slave.
Switch 2: Open left/Open right
Designates left or right opening.
Switch 3: Motor Brake - If the "on" position
is selected, the gate will stop instantly when
on the limit switches.
Switch 4: Close Timer (On/Off) - Sets the
Close
Auto-close timer can be ajusted from 1
to 60 seconds
(11)
Control Board
Timer to the "on" or "off" position.