Weiser Smartcode 10 Programming And Troubleshooting Manual page 13

Weiser smartcode 10 touchscreen electronic deadbolt
Hide thumbs Also See for Smartcode 10:
Table of Contents

Advertisement

C
The door handing process does not happen
automatically when the batteries are installed.
The handing process may have been executed
previously.
Follow the instructions inside the Installation and User Guide to perform
the manual door handing process
D
The touchscreen indicates a failure after the door handing process.
E
The deadbolt latch does not extend or retract on its own during
the door handing process.
The hole in the door is misaligned.
Disassemble the lock, and reinstall it without the adapter ring on the
exterior side of the door.
The mounting plate is placing tension on the
torque blade.
See page 12.
USA: 1-800-677-5625
Canada: 1-800-501-9471
www.weiserlock.com
The battery level is too low.
This is indicated by the Checkmark and Lock symbols fl ashing
simultaneously fi ve times with fi ve beeps. Use a fresh set of batteries, and
perform the door handing process again.
The battery level is too low.
This is indicated by the Checkmark and Lock symbols fl ashing
simultaneously fi ve times with fi ve beeps. Use a fresh set of batteries,
and perform the manual door handing process.
The latch and strike are misaligned, causing
the latch to bind.
Perform the manual door handing process while the door is open. If it
is successful only when the door is open, the latch and strike are not
aligned as they should be. Ensure door preparation is in accordance with
the door drilling instructions, available online.
13 / 15
62812 / 01
©2015 Spectrum Brands, Inc.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Smartcode 10 and is the answer not in the manual?

Questions and answers

caroline chapman
April 8, 2025

what would the master code usually be

1 comments:
Mr. Anderson
April 9, 2025

The Mastercode for the Weiser Smartcode 10 is not set by default. It must be manually enabled and programmed by the user. The Mastercode must be 4 to 8 digits long.

This answer is automatically generated