Exploding gas/ air mixture!
Danger to life from flying parts and burns
SIHI_0008_GB
1. Switch off control unit.
2. Ensure that the material pressure is relieved and shut off the atomizing air supply to
the gun.
3. Connect the detergent supply.
4. Set material pressure.
5. Actuate the trigger guard. Flush the gun through thoroughly.
6. Relieve the pressure of gun and unit!
7. Remove nozzle and clean separately.
8. Clean the spray gun body with a cleaning agent recommended by the manufacturer
and dry with a cloth or blow gun.
Cleaning agent in the air duct!
Functional faults caused by swollen seals
Discharge current to ground -> no high voltage
Always point the spray gun down when cleaning.
Ensure that neither paint nor cleaning agent enters the air duct.
When taking a break from work or when stored for a longer period, the spray gun
has to be positioned correctly with the attachment pointing downwards.
SIHI_0145_GB
ORDER NUMBER DOC 2319149
Never spray into a closed container.
Earth the container.
CAUTION
DANGER
B_03447
GM 5000EA