EDITION 03/2012
OPERATING MANUAL
Earthing scheme (example)
Control unit
Earthing
cable
Pump or
pressure tank
Paint container
or container for
return fl ow
B_03234
ORDER NUMBER DOC 2319149
Note for the sprayer
The work shoes and if used
the gloves must be
derivable.
Floor, derivable
Minimum cable cross-section
Control unit
4 mm² (AWG 12)
Pump
4 mm² (AWG 12)
Paint container
4 mm² (AWG 12)
Conveyor
16 mm² (AWG 6)
Booth
16 mm² (AWG 6)
Spraying stand
16 mm² (AWG 6)
GM 5000EA
Conveyor
Work piece
R max < 1 MΩ
Spraying stand
26