Diagnostic Error Code
018-199-XXX PCI Card test failed, cause unknown
018-250-XXX PCI Card Services error
020-000-XXX PCI Interface Test Passed
020-0XX-XXX PCI Interface error
020-195-XXX PCI Test aborted by user
020-196-XXX PCI test halt, error threshold exceeded
020-197-XXX PCI test warning
020-198-XXX PCI test aborted
020-199-XXX PCI test failed, cause unknown
020-262-XXXPCI system error
025-000-XXXIDE interface Test Passed
025-00X-XXX 025-01X-XXX IDE interface failure
FRU/Action
1. Go to "Undetermined problems" on page 67
2. Flash the system and re-test. See "Flash update
procedures" on page 185
3. Replace component under function test
1. PCI card
2. Riser card, if installed
3. System board
No action
1. PCI card
2. Riser card, if installed
3. System board
Information only Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called out
is connected and/or enabled. See Chapter 6
"Diagnostics, Test and Recovery Information" on
page 41
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
"Diagnostics, Test and Recovery Information" on
page 41
2. Flash the system and re-test. See "Flash update
procedures" on page 185
3. Go to "Undetermined problems" on page 67
1. Go to "Undetermined problems" on page 67
2. Flash the system and re-test. See "Flash update
procedures" on page 185
3. Replace component under function test
1. PCI card
2. Riser card, if installed
3. System board
No action
1. IDE signal cable
2. Check power supply voltages
3. Reseat IDE signal cable
4. IDE device
5. System board
Chapter 7
.
Symptom-to-FRU Index
55