Step
Figure
7
8
9
10
11
12
13
Discription
The EMI Sheet C (A351) is put in
the convex for positioning of a
Main Cover ASSY (AA01), and it
fixes.
Connect the lead wire and FPC of
Battery Case ASSY (AC11) to
MAIN PCB ASSY (U001).
Set the MAIN PCB ASSY (U001)
to body.
The EMI Sheet C (A351) is
separated easily so be careful.
Use the screws A326*2 and fix
MAIN PCB ASSY (U001),and
connect the FPC from SENSOR
PCB ASSY (U006).
Use the Screw A326 and install
the EMI Sheet B (A350).
EMI Sheet A (A349) joints to a
Main Cover ASSY (AA01) and it
fixes with screw A326.
Insulating tape is stuck on the
portion of the TERMINAL PCB
ASSY (UA11) as shown. (Two
Place)
35
Remark
Be careful, the lead wire from a
Battery Case ASSY (AC11) is not
to insert, check the position of
lead wire.
Before stopping a screw, a
position is united with tweezers so
that the hole and screw hole of the
EMI Sheet C (A351) may suit.
Cover a through-hole with
insulating tape.