Step
Figure
13
14
15
16
17
18
19
Discription
Take off the Screw Cap (A110)
and remove the screws A326.
Open the LCD monitor and
remove the screws A331*2.
Remove the Back Cover ASSY
(AA08) and remove the connector
of 3-WAY FPC (U008).
The connector of 3-WAY FPC
ASSY (U008) connected to the
MAIN PCB ASSY (U001) and the
JACK PCB ASSY (U002) is
removed.
Remove the screw A324.
The connector of Microphone
ASSY (HA56) remove to the JACK
PCB ASSY (UA02) and Top Cover
ASSY (AA06) is raised and
removed from a flash side.
Detach the Top Cover ASSY
(AA06) and the connector of
Microphone ASSY (HA56).
29
Remark
Pushing the lug with tweezers and
remove the Screw Cap (A110)
from inner side.
Remove the screws and close the
LCD monitor.
Top Cover ASSY (AA06) has lug
LCD side , it lift up and remove
from a flash side.
This work is unnecessary when
not exchanging the Top Cover
ASSY (AA06) and the connector
of Microphone ASSY (HA56).